O1D300

  • Reliable optical level measurement with high ranges up to 9.8 m
  • Scalable measuring range and window function
  • Two switching outputs, one of them programmable as analogue output
  • Wide range of components for quick mounting and precise fine adjustment
  • Excellent price/performance ratio

 

SKU: O1D300

$362,20

Description

Product characteristics
Laser protection class 2
Housing rectangular
Electrical data
Operating voltage [V] 18…30 DC; (“supply class 2” to cULus)
Current consumption [mA] < 150
Protection class III
Reverse polarity protection yes
Typ. lifetime [h] 50000
Measuring principle photoelectric
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1
Outputs
Total number of outputs 2
Electrical design PNP
Number of digital outputs 2
Output function normally open / normally closed; (programmable)
Max. current load per output [mA] 200
Number of analogue outputs 1
Analogue current output [mA] 4…20; (IEC 61131-2)
Max. load [Ω] 250
Analogue voltage output [V] 0…10; (IEC 61131-2)
Min. load resistance [Ω] 5000
Short-circuit protection yes
Type of short-circuit protection pulsed
Overload protection yes
Detection zone
Max. light spot width [mm] 15
Max. light spot height [mm] 15
Light spot dimensions refer to 10 m
Background suppression [m] 10…100
Measuring/setting range
Measuring range [m] 0.2…10; (white paper 200 x 200 mm 90% remission)
Sampling rate [Hz] 1…33
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9
Profiles Smart Sensor: Sensor Identification; Binary Data Channel; Process Value; Sensor Diagnosis
SIO mode yes
Required master port type A
Process data analogue 2
Process data binary 2
Min. process cycle time [ms] 6
Supported DeviceIDs
Type of operation DeviceID
Default 813
Operating conditions
Ambient temperature [°C] -10…60
Protection IP 67
Tests / approvals
EMC
EN 60947-5-2
Laser protection class 2
Notes on laser protection
Caution: laser light
Power: <= 4,0 mW
Wave length: 650 nm
pulse: 1,3 ns
Do not stare into beam.
Avoid exposure to the laser light.
laser class: 2
EN / IEC60825-1:2007
EN / IEC60825-1:2014
Complies with 21 CFR 1040 except for deviations pursuant to Laser Notice No. 50, dated June 2007.
MTTF [years] 107
Mechanical data
Weight [g] 325.5
Housing rectangular
Dimensions [mm] 59 x 42 x 52
Materials housing: diecast zinc; front pane: glass; LED window: PC
Lens alignment side lens
Displays / operating elements
Display
switching status 2 x LED, yellow
operation LED, green
distance value, programming alphanumeric display, 4-digit
Accessories
Accessories (optional)
Protective cover, E21133
Remarks
Remarks
operating voltage “supply class 2” according to cULus
Pack quantity 1 pcs.
Electrical connection
Connection Connector: 1 x M12; coding: A
Other data
Parameter Setting range Factory setting
Uni cm, m, inch cm
OU1 Hno, Hnc, Fno, Fnc Hno
SP1 [cm] 20.0…999.5 100.0
rP1 [cm] 20.0…999.5 80.0
OU2 Hno, Hnc, Fno, Fnc, I, U I
SP2 [cm] 20.0…999.5 200.0
rP2 [cm] 20.0…999.5 180.0
ASP [cm] 20.0…999.5 0
AEP [cm] 20.0…999.5 979.5
dr1 [s] 0…0.1…5 0
dr2 [s] 0…0.1…5 0
FOU1 ON ; OFF OFF
FOU2 ON ; OFF OFF
dFO [s] 0…0.1…5 0
EMP [cm] 20.0…999.5 20.0
cMEd [cm] 20.0…999.5
dIS ON ; OFF ON
mEAn [s] OFF ; 1…60 OFF
rATE [Hz] 1…33 15
repeatability/accuracy
repeatability of the measured values accuracy
white (90 % remission) grey (18 % remission) white (90 % remission) grey (18 % remission)
20.0…100.0 cm ± 0.45 cm ± 0.6 cm ± 1.5 cm ± 1.6 cm
100.0…200.0 cm ± 0.5 cm ± 0.8 cm ± 1.5 cm ± 1.8 cm
200.0…400.0 cm ± 1.6 cm ± 1.9 cm ± 2.5 cm ± 3.0 cm
400.0…600.0 cm ± 2.4 cm ± 3.3 cm ± 3.5 cm ± 4.5 cm
600.0…1000.0 cm ± 5.0 cm ± 6.5 cm
Sampling rate 15Hz
Extraneous light on the object < 40 klx
repeatability/accuracy
repeatability of the measured values accuracy
white (90 % remission) grey (18 % remission) white (90 % remission) grey (18 % remission)
20.0…200.0 cm ± 1.4 cm ± 1.4 cm ± 2.4 cm ± 2.4 cm
200.0…400.0 cm ± 2.5 cm ± 3.0 cm ± 3.5 cm ± 4.0 cm
400.0…600.0 cm ± 3.1 cm ± 4.5 cm ± 4.1 cm ± 5.5 cm
600.0…1000.0 cm ± 6.0 cm ± 7.0 cm
Sampling rate 15Hz
Extraneous light on the object 40…100 klx
repeatability/accuracy
repeatability of the measured values accuracy
white (90 % remission) grey (18 % remission) white (90 % remission) grey (18 % remission)
20.0…100.0 cm ± 0.4 cm ± 0.45 cm ± 1.4 cm ± 1.5 cm
100.0…200.0 cm ± 0.45 cm ± 0.6 cm ± 1.5 cm ± 1.6 cm
200.0…400.0 cm ± 1.35 cm ± 1.4 cm ± 2.3 cm ± 2.4 cm
400.0…600.0 cm ± 1.9 cm ± 2.1 cm ± 2.9 cm ± 3.1 cm
600.0…1000.0 cm ± 3.7 cm ± 4.7 cm
Sampling rate 1 Hz
Extraneous light on the object < 40 klx
repeatability/accuracy
repeatability of the measured values accuracy
white (90 % remission) grey (18 % remission) white (90 % remission) grey (18 % remission)
20.0…200.0 cm ± 1.0 cm ± 1.0 cm ± 2.0 cm ± 2.0 cm
200.0…400.0 cm ± 1.8 cm ± 1.9 cm ± 2.8 cm ± 2.9 cm
400.0…600.0 cm ± 2.3 cm ± 2.7 cm ± 3.3 cm ± 3.7 cm
600.0…1000.0 cm ± 3.8 cm ± 4.8 cm
Sampling rate 1 Hz
Extraneous light on the object 40…100 klx
Range on black object (6 % remission) <= 4000 mm
The values apply at
constant ambient conditions 23 °C / 960 hPa
minimum power-on time in minutes 10

 

O1D300.PDF

Datasheet
EN PDF

Reviews

There are no reviews yet.

Be the first to review “O1D300”

Your email address will not be published. Required fields are marked *