| Symbol |
00995693 |
| Degree of protection |
IP40 |
| Note on degree of protection |
IP51 for horizontal installation |
| Flow rate control range |
0 l/min … 20 l/min |
| Note on the flow rate control range |
The specified flow control range only applies at room temperature. Above room temperature, a reduction of the max. adjustable flow rate may occur. |
| Flow direction |
Non-reversible |
| Operating pressure |
0 MPa … 0.25 MPa |
| Operating pressure |
0 bar … 2.5 bar |
| Overload pressure |
0.6 MPa |
| Overload pressure |
6 bar |
| Overload pressure |
87 psi |
| Burst pressure |
1 MPa |
| Burst pressure |
10 bar |
| Burst pressure |
145 psi |
| Accuracy of flow rate |
± (4% o.m.v. + 1.25% FS) |
| Repetition accuracy in ± %FS |
1 %FS |
| Hysteresis in ± %FS |
2.5 %FS |
| Linearity error FS |
2 % |
| Temperature coefficient |
0.1 %/K |
| Valve function |
2-way proportional flow control valve |
| Nominal width |
1.4 mm |
| Pneumatic connection 1 |
Internal thread M5 |
| Pneumatic connection 2 |
Internal thread M5 |
| Medium |
Compressed air to ISO 8573-1:2010 [5:4:1]Inert gasOxygen (oxygen applications according to IEC 60601-1 only on request)Nitrogen |
| Information on medium |
Operation with oil lubrication not possible |
| Special features |
Oxygen-compatible as per DIN EN 1797 |
| Ambient conditions |
Not suitable for use in environments enriched with oxygen according to IEC 60601-1 |
| Duty cycle |
100% |
| Temperature of medium |
5 °C … 40 °C |
| Ambient temperature |
0 °C … 50 °C |
| Storage temperature |
-20 °C … 70 °C |
| Nominal operating voltage DC |
24 V |
| DC operating voltage range |
22 V … 26.4 V |
| Max. current consumption |
40 mA |
| Max. electrical power consumption |
1 W |
| Electrical connection |
4-pinM8x1 A-coded as per EN 61076-2-104Plug |
| Reference value |
0.2 – 10 V |
| Analog input signal range |
0.2 – 10 V |
| Analog output signal range |
0.2 – 10 V |
| Reverse polarity protection |
for operating voltage connections |
| Product weight |
92 g |
| Seals material |
EPDMNBR |
| Cover material |
PA-reinforced |
| Note on materials |
RoHS-compliant |
| Dimensions W x L x H |
37 mm x 70 mm x 31 mm |
| Type of mounting |
Direct fastening via thread |
| Mounting position |
Any |
| Certification |
RCM compliance mark |
| Conforms to standard |
EN 61000-6-2 (EMC)EN 61000-6-3 (EMC) |
| KC characters |
KC EMC |
| CE marking (see declaration of conformity) |
As per EU EMC directiveAs per EU RoHS directive |
| UKCA marking (see declaration of conformity) |
To UK instructions for EMCTo UK RoHS instructions |
| LABS (PWIS) conformity |
VDMA24364 zone III |