Dimensions W x L x H |
(incl. interlinking block)50 mm x 107 mm x 50 mm |
Fieldbus interface |
2x socket, M12x1, 4-pin, D-coded |
Device-specific diagnostics |
Channel-oriented and module-oriented diagnosticsUndervoltage of modulesDiagnostic memory |
Parameterization |
Diagnostic behaviorFail-safe responseforcing of channelsIdle mode performanceSignal setupSystem parameter |
Configuration support |
EDS fileL5K export with CPX-FMT |
Additional functions |
Acyclic data access via “Explicit Message”Acyclic data access via EthernetEtherNet/IP QuickconnectIP addressing via DHCP, DIL switch or operator unitIntegrated switchChannel-based diagnostics via fieldbusRing topology (DLR)Start-up parameterization in plain text via fieldbusSystem status can be indicated via process data |
Control elements |
DIL switch |
Baud rate |
10/100 Mbit/s |
DC operating voltage range |
18 V … 30 V |
Intrinsic current consumption at nominal operating voltage |
Typ. 100 mA |
Nominal operating voltage DC |
24 V |
Corrosion resistance class (CRC) |
1 – Low corrosion stress |
LABS (PWIS) conformity |
VDMA24364-B2-L |
Storage temperature |
-20 °C … 70 °C |
Degree of protection |
IP65IP67 |
Ambient temperature |
-5 °C … 50 °C |
Product weight |
125 g |
Max. address capacity outputs |
64 byte |
Max. address capacity inputs |
64 byte |
Protocol |
EtherNet/IPModbus® TCP |
LED display (bus-specific) |
MS: module statusNS: network statusTP1: network active port 1TP2: network active, port 2 |
LED display (product-specific) |
M: Modify, parameterizationPL: load supplyPS: electronics supply, sensor supplySF: system fault |
Note on materials |
RoHS-compliant |
Housing material |
PA-reinforced |