Structural design |
Rocker valve with diaphragm seal |
Sealing principle |
Soft |
Materials in contact with the media |
FPMPEEK |
For use in the food industry |
See supplementary material information |
Valve function |
2/2, open, monostable |
Nominal width |
1.2 mm |
Flow direction |
Reversible with restrictions |
Actuation type |
Electrical |
Type of control |
Direct |
Reset method |
Mechanical spring |
Manual override |
None |
Mounting position |
Any |
Type of mounting |
With through-hole for M2 screw |
Electrical connection 1, connection type |
Socket |
Electrical connection 1, connection technology |
Connection diagram Q7 |
Electrical connection 1, number of pins/wires |
2 |
Electrical connection for input 1, connection pattern |
00997312 |
Size |
7 |
Width dimension |
7.5 mm |
Fluid connector |
Flange |
Medium |
Liquid mediaGaseous media |
Information on medium |
Observe resistance of materials that come into contact with mediaMaximum particle size 5 µm |
Internal volume |
15 µl fluid space valve21 µl valve with fluid connections |
Temperature of liquid media |
0 °C … 50 °C |
Medium temperature gaseous media |
0 °C … 50 °C |
Ambient temperature |
0 °C … 50 °C |
Storage temperature |
-20 °C … 70 °C |
Medium pressure |
0 MPa … 0.2 MPa |
Medium pressure |
0 bar … 2 bar |
Medium pressure |
0 psi … 29 psi |
Note on the medium pressure |
IN: 0 – 2 bar / 0 – 0.2 MPa / 0 – 29 psiOUT: 0 – 1 bar / 0 – 0.1 MPa / 0 – 14.5 psi |
Burst pressure |
2.3 MPa |
Burst pressure |
23 bar |
Burst pressure |
333.5 psi |
DC operating voltage range |
12 V … 26 V |
Note on operating voltage range DC |
With electrical sub-base VAVE-K1-… |
Permissible voltage fluctuations |
+/- 10 % |
Electrical power consumption |
3.5 W |
Note on power consumption |
Low-current phase 0.3 W, high-current phase 3.5 W for 60 ms, in combination with VAVE-K1-… |
Coil characteristics |
12 – 26 V DC: low-current phase 0.06 W, high-current phase 2.2 W |
Insulation class |
B |
Duty cycle |
100% in combination with holding current reductionFollow the instructions on operating the air solenoid valves. |
Max. switching frequency |
6 Hz |
Note on switching frequency |
Dependent on the ambient temperature and installation stateAt 100% duty cycle depending on ambient temperature and installation condition. Higher switching frequencies possible with duty cycle < 100%. |
Response time “off” for liquid media |
6 ms |
Switching time off gaseous media |
4 ms |
Standard nominal flow rate |
7 l/min |
Note on standard nominal flow rate |
At a pressure drop of 1 -> 0 bar (gaseous media) |
Flow rate Kv |
0.013 m³/h |
Flow rate Kv |
0.22 l/min |
Note on flow rate Kv |
For the medium waterPressure difference 1 bar |
Water flow rate at max. operating pressure |
0.3 l/min0.018 m³/h |
Symbol |
00995700 |
Housing material |
PA-reinforcedPEEKPPA-reinforced |
Diaphragm material |
FPM |
Seals material |
FPM |
Note on materials |
RoHS-compliant |
LABS (PWIS) conformity |
VDMA24364 zone III |
Product weight |
10.9 g |
Degree of protection |
IP40 |
Note on degree of protection |
In mounted state |
Application note |
For indoor use only |
Corrosion resistance class (CRC) |
0 – No corrosion stress |
Reviews