Dimensions W x L x H |
45 mm x 170 mm x 35 mm |
Diagnostics via LED |
Buffer error LED (BF)Diagnostics per modulePower supply for electronics/sensorsLoad power supplySystem diagnosticsMaintenance required |
Diagnostics via bus |
APDD invalidLoad switch-offCommunication with AP module interruptedElectronics/sensors overvoltageLoad overvoltageElectronics/sensors undervoltageLoad undervoltage |
Configuration support |
GSD file |
Reverse polarity protection |
yes |
Max. number of modules |
56 |
Intrinsic current consumption at nominal operating voltage for electronics/sensors |
Typically 80 mA |
Intrinsic current consumption at nominal operating voltage load |
Typically 5 mA |
Note regarding operating voltage |
SELV/PELV fixed power supplies requiredNote voltage drop |
Max. power supply |
2 x 4 A (external fuse required) |
Nominal operating voltage DC for electronics/sensors |
24 V |
Nominal operating voltage DC load |
24 V |
Power failure buffering |
10 ms |
Permissible voltage fluctuations for electronics/sensors |
± 25 % |
Permissible voltage fluctuations load |
± 25 % |
Power supply, function |
Incoming electronics/sensors and load |
Power supply, type of connection |
Plug |
Power supply, connection technology |
M8x1, A-coded as per EN 61076-2-104 |
Power supply, number of pins/wires |
4 |
Voltage forwarding, function |
Outgoing electronics/sensors and load |
Voltage forwarding, connection type |
Socket |
Voltage forwarding, connection technology |
M8x1, A-coded as per EN 61076-2-104 |
Voltage forwarding, number of pins/wires |
4 |
Certification |
RCM compliance mark |
KC characters |
KC EMC |
CE marking (see declaration of conformity) |
As per EU EMC directive |
UKCA marking (see declaration of conformity) |
To UK instructions for EMC |
Corrosion resistance class (CRC) |
1 – Low corrosion stress |
Storage temperature |
-40 °C … 70 °C |
Relative air humidity |
5 – 95 %Non-condensing |
Degree of protection |
IP65IP67 |
Note on degree of protection |
Unused connections sealed |
Ambient temperature |
-20 °C … 50 °C |
Product weight |
186 g |
Max. address capacity outputs |
244 byte |
Max. address capacity inputs |
244 byte |
Fieldbus interface, galvanic isolation |
yes |
Fieldbus interface, transmission rate |
1.5 Mbit/s12 Mbit/s187.5 kbit/s19.2 kbit/s3 Mbit/s500 kbit/s6 Mbit/s9.6 kbit/s93.75 kbit/s |
Fieldbus interface, type |
PROFIBUS |
Max. cable length |
50 m system communication |
Fieldbus interface, function |
Incoming bus connection |
Fieldbus interface, connection type |
Plug |
Fieldbus interface, connection technology |
M12x1, B-coded as per EN 61076-2-101 |
Fieldbus interface, number of poles/wires |
5 |
Fieldbus interface, protocol |
PROFIBUS DP-V1 |
Fieldbus interface 2, connection type |
Socket |
Fieldbus interface 2, connection technology |
M12x1, B-coded as per EN 61076-2-101 |
Fieldbus interface 2, number of poles/wires |
5 |
Fieldbus interface 2, function |
Bus connection, forwarding |
Fieldbus interface 2, type |
PROFIBUS |
Fieldbus interface 2, protocol |
PROFIBUS DP-V1 |
Fieldbus interface 2, galvanic isolation |
yes |
Fieldbus interface 2, transmission rate |
1.5 mbps12 mbps187.5 kbps19.2 kbps3 mbps500 kbps6 mbps9.6 kbps93.75 kbps |
Communication interface, function |
System communication XF20 OUT / XF21 OUT |
Communication interface, connection type |
2x socket |
Communication interface, connection technology |
M8x1, D-coded as per EN 61076-2-114 |
Communication interface, number of pins/wires |
4 |
Communication interface, protocol |
AP-COM |
Communication interface, shielding |
yes |
Note on fieldbus interface |
Terminating resistor on socket possible |
Type of mounting |
On H-rail with accessoriesWith through-hole |
Note on materials |
RoHS-compliant |
Housing material |
PAPCDie-cast zinc, nickel-plated |
O-ring material |
FPM |