| Design |
Rectangular |
| Based on norm |
EN 60947-5-6VDI/VDE 3845 |
| Certification |
RCM compliance markc UL us (OL) |
| CE marking (see declaration of conformity) |
As per EU EMC directiveas per EU explosion protection directive (ATEX)As per EU RoHS directive |
| Explosion prevention and protection |
Zone 0 (ATEX)Zone 1 (ATEX)Zone 2 (ATEX)Zone 0 (IEC-EX)Zone 0 (CN)Zone 20 (CN) |
| ATEX category gas |
II 1G |
| Type of ignition protection for gas |
Ex ia IIC T6…T1 Ga |
| Explosion protection certification outside the EU |
EPL Da (CN)EPL Ga (CN)EPL Ga (IEC-EX) |
| Explosive ambient temperature |
See ATEX certificateSee IECEx certificate |
| Effective internal inductance Li |
100 µH |
| Effective internal capacitance Ci |
100 nF |
| Max. input parameter of intrinsically safe circuit |
See IECEx certificateSee ATEX certificate |
| Certificate issuing authority |
GYJ20.1662XIECEx TUN 18.0003XGerman Technical Control Board (TÜV) 16 ATEX 174269 X |
| Note on materials |
RoHS-compliant |
| Safety integrity level (SIL) |
SIL 2 |
| Measuring principle |
Inductive |
| Ambient temperature |
-25 °C … 100 °C |
| Switching output |
NAMUR |
| Switching element function |
N/C contact |
| Max. switching frequency |
3000 Hz |
| Max. output current DC |
3 mA |
| Short-circuit protection |
yes |
| DC operating voltage range |
8.2 V |
| Reverse polarity protection |
for all electrical connections |
| Electrical connection 1, connection type |
Terminal strip |
| Electrical connection 1, cable outlet |
Straight |
| Electrical connection 1, design |
Round |
| Electrical connection 1, connection technology |
Spring-loaded terminal |
| Electrical connection 1, number of pins/wires |
10 |
| Electrical connection for input 1, connection pattern |
00995598 |
| Closable nominal conductor cross-section |
0.2 mm² … 2.5 mm² |
| Cable fitting |
M12x1.5M20x1.5 |
| Type of mounting |
Threaded |
| Mounting position |
Any |
| Product weight |
170 g |
| Housing material |
PBT |
| Material of screws |
High-alloy stainless steel |
| Switching status indication |
LED yellow |
| Status indicator |
LED yellow = pneumatic valve switching status |
| Storage temperature |
-40 °C … 100 °C |
| Degree of protection |
IP67 |
| Shock resistance |
Shock test with severity level 2 as per FN 942017-5 and EN 60068-2-27 |
| Vibration resistance |
Transport application test with severity level 2 as per FN 942017-4 and EN 60068-2-6 |
| LABS (PWIS) conformity |
VDMA24364 zone III |
| Contamination level |
3 |