CIP Safety

From a production line to a
single machine safety solution

Quick, easy, and flexible to integrate safety into production lines

  • 1 built-in EtherNet/IP port (100Base-TX)
  • 2 built-in CIP-Safety on EtherNet/IP ports
  • Up to 254 safety connections with NX-SL5700
  • Up to 32 NX I/O Units per Communication Control Unit
  • Multi-cast packet possible
  • Possible hybrid solution combining NX1 controller with NX-SL5000 series

Specifications & ordering info

Ordering Information

NX1 series CPU units

CPUAppearanceProgram capacityVariables capacityNumber of axesFunctionalitiesOrder code
Real axesMotion control servo axesSingle-axis position control axesSequenceOPC UAMotionDB connection
NX1025 MB

1.5 MB: Retained

32 MB: Not retained

12 axes8 axes4 axesNX102-1220
NX102-1200
8 axes4 axesNX102-1120
NX102-1100
6 axes2 axesNX102-1020
NX102-1000
4 axes0 axesNX102-9020
NX102-9000
Note:

The end cover unit NX-END02 is included with the CPU unit.

NX-series Safety Control Units

Safety CPU Units

Unit typeAppearanceSpecificationsUnit versionOrder code
Maximum number of safety I/O pointsProgram capacityNumber of safety I/O connectionsI/O refreshing method
Safety CPU Unit
(NX-SL5⬜⬜⬜)
1024 points2048 KB128Free-Run refreshingVer. 1.3NX-SL5500
2032 points4096 KB254NX-SL5700
Note:

Refer to your local OMRON website for details of the NX-SL5⬜⬜⬜ Safety CPU Unit.

Safety Input Units

Unit typeAppearanceSpecificationsUnit versionOrder code
Number of safety input pointsNumber of test output pointsInternal I/O commonRated input voltageOMRON special safety input devicesNumber of safety slave connectionsI/O refreshing method
Safety Input Units4 points2 pointsSinking inputs (PNP)24 VDCCannot be
connected.
1Free-Run refreshingVer. 1.1NX-SIH400
8 pointsCannot be
connected.
Ver. 1.0NX-SID800

Safety Output Units

Unit typeAppearanceSpecificationsUnit versionOrder code
Number of
safety output
points
Internal I/O
common
Maximum load currentRated
voltage
Number of
safety slave
connections
I/O refreshing
method
Safety Output Units2 pointsSourcing
outputs
(PNP)

2.0 A/point, 4.0 A/Unit at 40°C, and 2.5 A/Unit at 55°C

The maximum load current depends on the installation orientation and ambient temperature.

24 VDC1Free-Run refreshingVer. 1.0NX-SOH200
4 points0.5 A/point and 2.0 A/UnitNX-SOD400

NX-series Standard I/O units

For the selection of standard I/O units please refer to the NX Series product website (https://industrial.omron.eu/en/products/nx-series).

Automation Software Sysmac Studio

Please purchase a DVD and required number of licenses the first time you purchase the Sysmac Studio. DVDs and licenses are available individually. Each model of licenses does not include any DVD.

Product nameSpecificationsNumber of licensesMediaOrder code
Sysmac Studio
Safety Edition
Ver. 1.⬜⬜

Sysmac Studio Safety Edition is a license including necessary setting functions for the safety control system.

Note:This product is a license only. You need the Sysmac Studio Standard Edition DVD media to install it.
1 licenseSYSMAC-FE001L
Sysmac Studio
Standard Edition
Ver. 1.⬜⬜

The Sysmac Studio is the software that provides an integrated environment for setting, programming, debugging and maintenance of machine automation controllers including the NJ/NX-series CPU Units, NY-series Industrial PC, EtherCAT Slave, and the HMI.

Sysmac Studio runs on the following OS.

Windows 7(32-bit/64-bit version)/8(32-bit/64-bit version)/8.1(32-bit/64-bit version)/10(32-bit/64-bit version)

– (Media only)DVDSYSMAC-SE200D
Note:

For details of the Automation Software Sysmac Studio, refer to your local OMRON website.

Optional Products

Product nameSpecificationsOrder code
Memory CardSD memory card, 2 GBHMC-SD291
SD memory card, 4 GBHMC-SD491
Unit/Terminal Block Coding PinsFor 10 Units (Terminal Block: 30 pins, Unit: 30 pins)NX-AUX02
Product nameSpecificationsOrder code
No. of terminalsTerminal number indicationsGround terminal markTerminal current capacity
Terminal Block8A/BProvided10 ANX-TBC082
8A/BNone10 ANX-TBA082
16A/BNone10 ANX-TBA162

Accessories

Communication Control Unit Accessories

Product nameRemarkOrder code
End CoverOne End Cover is provided with the Communication Control Unit.NX-END02

Specifications

Regulations and Standards

NX-series Safety Control Units

Certification bodyStandards
TÜV Rheinland EN ISO 13849-1EN ISO 13849-2IEC 61508 parts 1-7IEC/EN 62061IEC/EN 61131-2IEC 61326-3-1IEC 61131-6 
ULNRAQ (UL61010-1, and UL 61010-2-201)NRAG (ANSI/ISA 12.12.01, or UL 121201)NRAQ7 (CSA C22.2 No. 61010-1, and CSA C22.2 No. 61010-2-201)FSPC (IEC 61508 and ISO 13849) 
The NX-series Safety Control Units allow you to build a safety control system that meets the following standards.
– Requirements for SIL 3 (Safety Integrity Level 3) in IEC 61508, IEC/EN 62061, (Functional Safety of Electrical/Electronic/Programmable Electronic Safety-related Systems)
– Requirements for PLe (Performance Level e) and for safety category 4 in EN ISO13849-1

The NX-series Safety Control Units are also registered for RCM, EAC, and KC compliance.

General Specifications

ItemSpecifications
EnclosureMounted in a panel (open)
Grounding methodGround to 100 Ω or less
Operating
environment
Ambient operating temperature0 to 55°C
Ambient operating humidity10% to 95% (with no condensation or icing)
AtmosphereMust be free from corrosive gases.
Ambient storage temperature−25 to 70°C (with no condensation or icing)
Altitude2,000 m max.
Pollution degree2 or less: Conforms to JIS B3502 and IEC 61131-2.
Noise immunityConforms to IEC 61131-2.
2 kV on power supply line
Insulation classClass III (SELV)
Overvoltage categoryCategory II: Conforms to JIS B3502 and IEC 61131-2.
EMC immunity levelZone B
Vibration resistanceConforms to IEC 60068-2-6.
5 to 8.4 Hz with 3.5-mm amplitude
8.4 to 150 Hz, acceleration of 9.8 m/s2
100 minutes each in X, Y, and Z directions (10 sweeps of 10 min each = 100 min total)
Shock resistanceConforms to IEC 60068-2-27.
147 m/s2, 3 times each in X, Y, and Z directions
Insulation resistance20 MΩ between isolated circuits (at 100 VDC)
Dielectric strength510 VAC for 1 min between isolated circuits, leakage current: 5 mA max.
Installation methodDIN Track (IEC 60715 TH35-7.5/TH35-15)

Safety Control Units

Safety CPU Units NX-SL5500/SL5700

Unit nameSafety CPU Unit
ModelNX-SL5500NX-SL5700
Maximum number of safety I/O points1024 points2032 points
Program capacity2048 KB4096 KB
Number of safety master connections 128254
Number of CIP Safety originator connections128254
Number of CIP Safety target connections44
Number of originators that can be connected with
a multi-cast connection
88
Number of FSoE master connections128254
I/O refreshing methodFree-Run refreshing
External connection terminalsNone
Indicators[TS] indicator, [NS] indicator, [FS] indicator, [P ERR] indicator, [RUN] indicator,
[VALID] indicator, [DEBUG] indicator, seven-segment indicator
[TS] indicator, [NS] indicator, [FS] indicator, [P ERR] indicator, [RUN] indicator,
[VALID] indicator, [DEBUG] indicator, seven-segment indicator
Hardware switch settings[SERVICE] switch, [SETTING] switch[SERVICE] switch, [SETTING] switch
Dimensions30 × 100 × 71 mm (W × H × D)
I/O power supply methodNot supplied.
Current capacity of I/O power supply terminalsNo I/O power supply terminals
NX Unit power consumption3.35 W max. 
Current consumption from I/O power supplyNo consumption
Weight130 g max.
Installation orientation and restrictions

Installation orientation: Upright installation

Restriction

: None.

 

Safety Input Units NX-SIH400/SID800

Unit nameSafety Input Unit
ModelNX-SIH400NX-SID800
Number of safety input points4 points8 points
Number of test output points2 points2 points
Internal I/O commonPNP (sinking inputs)
Rated input voltage24 VDC (20.4 to 28.8 VDC)
OMRON special safety input
devices
Can be connected.Cannot be connected.
Number of safety slave
connections
1
I/O refreshing methodFree-Run refreshing
External connection terminalsScrewless clamping terminal block (8 terminals)Screwless clamping terminal block (16 terminals)
Indicators[TS] indicator, [FS] indicator, [IN] indicator, [IN ERR] indicator[TS] indicator, [FS] indicator, [IN] indicator, [IN ERR] indicator
Safety input current4.5 mA TYP.3.0 mA TYP.
Safety input ON voltage11 VDC min.15 VDC min.
Safety input OFF voltage/OFF
current
5 VDC max., 1 mA max.
Test output typeSourcing outputs (PNP)
Test output load current25 mA max.50 mA max.
Test output residual voltage1.2 V max. (Between IOV and all output terminals)
Test output leakage current0.1 mA max.
Dimensions12 × 100 × 71 mm (W × H × D)
Isolation methodPhotocoupler isolation
Insulation resistance20 MΩ min. between isolated circuits (at 100 VDC)
Dielectric strength510 VAC for 1 min between isolated circuits, leakage current: 5 mA max.
I/O power supply methodPower supplied from the NX bus
Current capacity of I/O power
supply terminals
No applicable terminals.
NX Unit power consumptionConnected to a CPU Unit or a Communication Control Unit 1.10 W max.Connected to a Communications Coupler Unit 0.70 W max.Connected to a CPU Unit or a Communication Control Unit 1.10 W max.Connected to a Communications Coupler Unit 0.75 W max.
Current consumption from I/O
power supply
20 mA max.
Weight70 g max.
Circuit layout
Terminal connection diagramSi0 to Si3: Safety input terminals
T0 and T1: Test output terminals

Refer to User’s manual (Cat. No. Z395) for details.

Si0 to Si7: Safety input terminals
T0 and T1: Test output terminals

Refer to User’s manual (Cat. No. Z395) for details.

Installation orientation and
restrictions

Installation orientation:

  • Connected to a CPU Unit or a Communication Control Unit  Possible in the upright installation orientation.
  • Connected to a Communications Coupler Unit 6 possible orientations.

Restrictions: Maximum ambient temperature is 50°C for any orientation other than upright installation.

Protective functionsOvervoltage protection circuit and short detection (test outputs)

Safety Output Units NX-SOH200/SOD400

Unit nameSafety Output Unit
ModelNX- SOH200NX- SOD400
Number of safety output points2 points4 points
Internal I/O commonPNP (sourcing outputs)
Maximum load current2.0 A/point
4.0 A/Unit at 40°C
2.5 A/Unit at 55°CThe maximum load current depends on the installation orientation and
ambient temperature
0.5 A/point and 2.0 A/Unit
Rated voltage24 VDC (20.4 to 28.8 VDC)
Number of safety slave
connections
1
I/O refreshing methodFree-Run refreshing
External connection terminalsScrewless clamping terminal block (8 terminals)
Indicators[TS] indicator, [FS] indicator, [OUT] indicator,
[OUT ERR] indicator
[TS] indicator, [FS] indicator, [OUT] indicator,
[OUT ERR] indicator
Safety output ON residual voltage1.2 V max. (Between IOV and all output terminals)
Safety output OFF residual voltage2 V max. (Between IOG and all output terminals)
Safety output leakage current0.1 mA max.
Dimensions12 × 100 × 71 mm (W × H × D)
Isolation methodPhotocoupler isolation
Insulation resistance20 MΩ min. between isolated circuits (at 100 VDC)
Dielectric strength510 VAC for 1 min between isolated circuits, leakage current: 5 mA max.
I/O power supply methodPower supplied from the NX bus
Current capacity of I/O power
supply terminals
IOG: 2 A max./terminalIOG (A3 and B3): 2 A max./terminal
IOG (A7 and B7): 0.5 A max./terminal
NX Unit power consumption
  • Connected to a CPU Unit or a Communication Control Unit 1.05 W max.
  • Connected to a Communications Coupler Unit 0.70 W max.
  • Connected to a CPU Unit or a Communication Control Unit 1.10 W max.
  • Connected to a Communications Coupler Unit 0.75 W max.
Current consumption from I/O
power supply
40 mA max.60 mA max.
Weight65 g max.
Circuit layout
Terminal connection diagramSo0 and So1: Safety output terminals
IOG: I/O power supply 0 V

Refer to User’s manual (Cat. No. Z395) for details.

So0 to So3: Safety output terminals
IOG: I/O power supply 0 V

Refer to User’s manual (Cat. No. Z395) for details.

Installation orientation and
restrictions

Installation orientation:

  • Connected to a CPU Unit or a Communication Control Unit
    Possible in the upright installation orientation.
  • Connected to a Communications Coupler Unit
    6 possible orientations.
Restrictions:
For upright installation, the ambient temperature is restricted as shown below depending on the total Unit load current.

For all installation orientations other than upright installation, the ambient temperature is restricted as shown below according to the total Unit load current.

Installation orientation:

  • Connected to a CPU Unit or a Communication Control Unit
    Possible in the upright installation orientation.
  • Connected to a Communications Coupler Unit
    6 possible orientations.

Restrictions:
None

Protective functionsOvervoltage protection circuit and short detection (test outputs)

Videos

Omron NX-Series Safety Network Controller

NX Series CIP Safety Controller with EtherCAT and Ethernet/IP capabilities. In addition to new hardware, Sysmac Studio new functions include Automatic Programming, Safety Data Logging, and Online Functional Test. For more information visit: USA Canada Mexico

Downloads

Safety Controller NX-Series

Brochure
ENPDF 2.63 MB

Safety Remote IO-GI Series

Users Manual
ENPDF 15.4 MB

Sysmac NX CSG320