The all-in-one design of the V680S RFID system provides simple installation. Communication via a Modbus TCP connection, ideal for industrial applications, makes system expansion possible with minimal effort. Configuration via the integrated web browser interface is fast and requires no additional software or special cables.
Type | Memory capacity | Appearance | Size | Installation | Order code |
---|---|---|---|---|---|
Battery-less | 2 kbytes | ![]() |
40 × 40 × 5 mm | For flush mounting on metallic surface | V680S-D2KF67M |
For flush mounting on nonmetallic surface | V680S-D2KF67 | ||||
![]() |
86 × 54 × 10 mm | For flush mounting on metallic surface | V680S-D2KF68M | ||
For flush mounting on nonmetallic surface | V680S-D2KF68 | ||||
8 kbytes | ![]() |
40 × 40 × 5 mm | For flush mounting on metallic surface |
V680S-D8KF67M |
|
For flush mounting on nonmetallic surface |
V680S-D8KF67 |
||||
![]() |
86 × 54 × 10 mm | For flush mounting on metallic surface |
V680S-D8KF68M |
||
For flush mounting on nonmetallic surface |
V680S-D8KF68 |
Type | Memory capacity | Appearance | Size | Installation | Order code |
---|---|---|---|---|---|
Battery-less | 1 kbyte | ![]() |
20 dia. × 2.7 mm | For flush mounting on nonmetallic surface | V680-D1KP54T |
![]() |
34 × 34 × 3.5 mm | For flush mounting on metallic surface | V680-D1KP66MT | ||
For flush mounting on nonmetallic surface | V680-D1KP66T | ||||
Environment-resistant type Battery-less |
![]() |
95 × 36.5 × 6.5 mm | For flush mounting on nonmetallic surface | V680-D1KP66T-SP | |
High-temperature type Battery-less |
![]() |
80 dia. × t10 mm | For mounting with special attachment | V680-D1KP58HTN |
Note:
V680 series 8kbyte RF Tag (V680-D8KF67,V680-D8KF67M and V680-D8KF68A) can communicate with V680S series Reader/Writer. For details, refer to the User’s Manual (Cat. No. Z339).
Type | Appearance | Size | Network | Order code |
---|---|---|---|---|
Reader/Writer | ![]() |
50 × 50 × 30 mm | EtherNet/IP | V680S-HMD63-EIP |
PROFINET | V680S-HMD63-PNT | |||
![]() |
75 × 75 × 40 mm | EtherNet/IP | V680S-HMD64-EIP | |
PROFINET | V680S-HMD64-PNT | |||
![]() |
120 × 120 × 40 mm | EtherNet/IP | V680S-HMD66-EIP | |
PROFINET | V680S-HMD66-PNT | |||
![]() |
50 × 50 × 30 mm | Modbus TCP (TCP/IP) | V680S-HMD63-ETN | |
![]() |
75 × 75 × 40 mm | V680S-HMD64-ETN | ||
![]() |
120 × 120 × 40 mm | V680S-HMD66-ETN |
Type | Appearance | Order code |
---|---|---|
For the V680-D1KP66T | ![]() |
V600-A86 |
For the V680-D1KP58HTN | ![]() |
V680-A80 |
For the V680-D1KP54T | ![]() |
V700-A80 |
Type | Appearance | Length | Order code |
---|---|---|---|
Special connector – RJ45 | ![]() |
2 m | V680S-A41 2M |
5 m | V680S-A41 5M | ||
10 m | V680S-A41 10M | ||
Special connector – Loose wires | ![]() |
2 m | V680S-A42 2M |
5 m | V680S-A42 5M | ||
10 m | V680S-A42 10M |
Type | Appearance | Length | Order code |
---|---|---|---|
Special connector – Special connector | ![]() |
10 m | V680S-A40 10M |
20 m | V680S-A40 20M | ||
50 m | V680S-A40 50M |
Note: The maximum extendable cable length using the cable and extension cable is 60 m. Only one extension cable can be used.
Type | Appearance | Specifications | Order code | ||
---|---|---|---|---|---|
Functions | No. of ports | Failure detection | |||
Industrial switching hubs | ![]() |
Quality of Service (QoS): EtherNet/IP control data priority Failure detection: Broadcast storm and LSI error detection 10/100BASE-TX, Auto-Negotiation |
3 | No | W4S1-03B |
![]() |
5 | No | W4S1-05B | ||
5 | Yes | W4S1-05C |
RFID Units | Appearance | Product name | Amplifier/Antenna | No. of unit numbers used |
Order code |
---|---|---|---|---|---|
NX-series RFID Units | ![]() |
RFID Units | V680 series | 1 | NX-V680C1 |
![]() |
2 | NX-V680C2 |
Item | V680S-D2KF67 | V680S-D2KF67M | V680S-D2KF68 | V680S-D2KF68M |
---|---|---|---|---|
Memory capacity | 2,000bytes (user area) | |||
Memory type | FRAM | |||
Data retention | 10 years after writing (85°C or less) | |||
Memory life |
One trillion writes for each block (85°C or less), Access frequency : One trillion accesses |
|||
Ambient operating temperature | −20 to 85°C (with no icing) | |||
Ambient storage temperature | −40 to 125°C (with no icing) | |||
Ambient operating humidity | 35% to 85% | |||
Degree of protection |
IP68 (IEC 60529:2001), Oil resistance equivalent to IP67G (JIS C 0920:2003, Appendix 1).IPX9K (DIN 40 050) |
|||
Vibration resistance | No abnormality after application of 10 to 2,000 Hz, 1.5-mm double amplitude, acceleration: 150 m/s², 10 sweeps each in X, Y, and Z directions for 15 minutes each | No abnormality after application of 10 to 500 Hz, 1.5-mm double amplitude, acceleration: 100 m/s², 10 sweeps each in X, Y, and Z directions for 11 minutes each | ||
Shock resistance | No abnormality after application of 500 m/s², 3 times each in X, Y, and Z directions (Total: 18 times) | |||
Dimensions (W×H×D) | 40 × 40 × 5 mm | 86 × 54 × 10 mm | ||
Materials | Exterior: PPS resin | |||
Weight | Approx. 11.5 g | Approx. 12 g | Approx. 44 g | Approx. 46 g |
Metal countermeasures | None | Provided | None | Provided |
Note: For details, refer to the User’s Manual (Cat. No. Z339).
Item | V680S-D8KF67 | V680S-D8KF67M | V680S-D8KF68 | V680S-D8KF68M |
---|---|---|---|---|
Memory capacity | 8,192 bytes (user area) | |||
Memory type | FRAM | |||
Data retention | 10 years after writing (85°C or less) | |||
Memory life |
One trillion writes for each block (85°C or less), Access frequency: One trillion accesses |
|||
Ambient operating temperature | −20 to 85°C (with no icing) | |||
Ambient storage temperature | −40 to 125°C (with no icing) | |||
Ambient operating humidity | 35% to 85% | |||
Degree of protection |
IP68 (IEC 60529:2001), Oil resistance equivalent to IP67G (JIS C 0920:2003, Appendix 1). IPX9K (DIN 40 050) |
|||
Vibration resistance | No abnormality after application of 10 to 2,000 Hz, 1.5-mm double amplitude, acceleration: 150 m/s², 10 sweeps each in X, Y, and Z directions for 15 minutes each | No abnormality after application of 10 to 500 Hz, 1.5-mm double amplitude, acceleration: 100 m/s², 10 sweeps each in X, Y, and Z directions for 11 minutes each | ||
Shock resistance | No abnormality after application of 500 m/s², 3 times each in X, Y, and Z directions (Total: 18 times) | |||
Dimensions (W×H×D) | 40 × 40 × 5 mm | 86 × 54 × 10 mm | ||
Materials | Exterior: PPS resin | |||
Weight | Approx. 11.5 g | Approx. 12 g | Approx. 44 g | Approx. 46 g |
Metal countermeasures | None | Provided | None | Provided |
Note: For details, refer to the User’s Manual (Cat. No. Z339).
Item | V680-D1KP54T | V680-D1KP66T | V680-D1KP66MT | V680-D1KP66T-SP |
---|---|---|---|---|
Memory capacity | 1,000 bytes (user area) | |||
Memory type | EEPROM | |||
Data retention time |
10 years after writing (85°C or less), 0.5 year after writing (85 to 125°C) |
10 years after writing (85°C or less) | ||
Write endurance | 100,000 writes for each block (25°C) | |||
Ambient operating temperature (during transmission) |
−25 to 85°C (with no icing) | During RF Tag communications: −25 to 70°C (with no icing)Not during RF Tag communications: −40 to 110°C (with no icing) |
||
Ambient storage temperature (during data backup) |
−40 to 125°C (with no icing) Heat resistance: 200 thermal cycles each of 30 minutes at −10°C/180°C, |
−40 to 110°C (with no icing) | ||
Ambient operating humidity | 35 to 95% | |||
Degree of protection |
IP67 (IEC 60529:2001) Oil resistance equivalent to IP67G |
IP68 (IEC 60529:2001) Oil resistance equivalent to IP67G |
IP67 | |
Vibration resistance | No abnormality after application of 10 to 2,000 Hz, 1.5-mm double amplitude, acceleration: 150 m/s², 10 sweeps each in X, Y, and Z directions for 15 minutes each |
|||
Shock resistance | No abnormality after application of 500 m/s², 3 times each in X, Y, and Z directions (Total: 18 times) | |||
Appearance | 20 dia. × 2.7 mm | 34 × 34 × 3.5 mm | 95×36.5×6.5 mm (excluding protruding parts) |
|
Materials | PPS resin |
Exterior: PFA fluororesin RF Tag filling: PPS resin |
||
Weight | Approx. 2 g | Approx. 6 g | Approx. 7.5 g | Approx. 20 g |
Metal countermeasures | None | None | Provided | None |
Note: For details, refer to the User’s Manual (Cat. No. Z339).
Item | V680-D1KP58HTN |
---|---|
Memory capacity | 1,000 bytes (user area) |
Memory type | EEPROM |
Data retention |
10 years after writing (85°C or less), 0.5 year after writing (85 to 125°C) Total data retention at high temperatures exceeding 125°C is 10 hours |
Write endurance | 100,000 writes for each block (25°C) |
Ambient operating temperature (during transmission) |
−25 to 85°C (with no icing) |
Ambient storage temperature (during data backup) |
−40 to 250°C (with no icing) (Data retention: −40 to 125°C) |
Ambient storage humidity | No restrictions. |
Degree of protection |
IP67 (IEC 60529:2001) Oil resistance equivalent to IP67G (JIS C 0920:2003, Appendix 1) |
Vibration resistance | No abnormality after application of 10 to 2,000 Hz, 1.5-mm double amplitude, acceleration: 150 m/s², 10 sweeps each in X, Y, and Z directions for 15 minutes each |
Shock resistance | No abnormality after application of 500 m/s², 3 times each in X, Y, and Z directions (Total: 18 times) |
Materials | Exterior: PPS resin |
Weight | Approx. 70 g |
Note: For details, refer to the User’s Manual (Cat. No. Z339).
Item |
V680S-HMD63-EIP V680S-HMD63-PNT |
V680S-HMD64-EIP V680S-HMD64-PNT |
V680S-HMD66-EIP V680S-HMD66-PNT |
---|---|---|---|
Dimensions (W×H×D) | 50×50×30mm (excluding protruding parts and cables) |
75×75×40mm (excluding protruding parts and cables) |
120×120×40mm (excluding protruding parts and cables) |
Power supply voltage | 24 VDC (−15% to 10%) | ||
Consumption current | 0.2 A max. | ||
Ambient operating temperature | −10 to +55°C (with no icing) | ||
Ambient operating humidity | 25% to 85% (with no condensation) | ||
Ambient storage temperature | −25 to 70°C (with no icing) | ||
Ambient storage humidity | 25% to 85% (with no condensation) | ||
Insulation resistance | 20 MΩ min. (at 500 VDC) between cable terminals and case | ||
Dielectric strength | 1,000 VAC, 50/60 Hz for 1 min between cable terminals and case | ||
Vibration resistance | No abnormality after application of 10 to 500 Hz, 1.5-mm double amplitude, acceleration: 100 m/s², 10 sweeps in each of 3 axis directions (up/down, left/right, and forward/backward) for 11 minutes each |
||
Shock resistance | No abnormality after application of 500 m/s², 3 times each in 6 directions (Total: 18 times) | ||
Degree of protection |
IP67 (IEC 60529: 2001) Oil resistance equivalent to IP67F (JIS C 0920: 2003, Appendix 1) |
||
Materials | Case: PBT resin, Filled resin: Urethane resin | ||
Mass | Approx. 240 g | Approx. 390 g | Approx. 760 g |
Installation method |
Reader/Writer: Two M4 screws Branch cable joint: One M4 screws |
Four M4 screws (Use a screw of 12 mm or more in length.) |
|
Host device communications interface | Ethernet 10BASE-T/100BASE-TX | ||
Host device communications protocol | EtherNet/IP, PROFINET | ||
Accessories | Instruction Sheet, Description of Regulations and Standard, IP address label |
Note: The 0.5 m cable with two M12 connectors is attached to the Reader/Writer. The cable cannot be removed.
Item | V680S-HMD63-ETN | V680S-HMD64-ETN | V680S-HMD66-ETN |
---|---|---|---|
Dimensions | 50×50× 30 (excluding protruding parts) |
75× 75× 40 (excluding protruding parts) |
120× 120× 40mm (excluding protruding parts) |
Power supply voltage | 24 VDC (–15% to 10%) | ||
Consumption current | 0.2A max. | ||
Ambient operating temperature | –10 to 55°C (with no icing) | ||
Ambient operating humidity | 25% to 85% (with no condensation) | ||
Ambient storage temperature | −25 to 70°C (with no icing) | ||
Ambient storage humidity | 25% to 85% (with no condensation) | ||
Insulation resistance | 20 MΩ min. (at 500 VDC) between cable terminals and case | ||
Dielectric strength | 1,000 VAC, 50/60 Hz for 1 min between cable terminals and case | ||
Vibration resistance | No abnormality after application of 10 to 500 Hz, 1.5-mm double amplitude, acceleration: 100 m/s², 10 sweeps in each of 3 axis directions (up/down, left/right, and forward/backward) for 11 minutes each |
||
Shock resistance | No abnormality after application of 500 m/s², 3 times each in 6 directions (Total: 18 times) | ||
Degree of protection |
IP67 (IEC 60529: 2001) Oil resistance equivalent to IP67F (JIS C 0920: 2003, Appendix 1) |
||
Materials | Case: PBT resin, Filled resin: Urethane resin | ||
Mass | Approx. 120 g | Approx. 270 g | Approx. 640 g |
Installation method | Two M4 screws (Use a screw of 12 mm or more in length.) |
Four M4 screws (Use a screw of 12 mm or more in length.) |
|
Host device communications interface |
Ethernet 10BASE-T/100BASE-TX | ||
Host device communications protocol |
MODBUS TCP | ||
Accessories |
Instruction sheet, Description of Regulations and Standard, IP address label, Ferrite core |
The below shows the configuration for 1 to 1 connection. Multiple Reader/Writers can be connected by using a switching hub.
Operation Manual
ENPDF 3.42 MB
Connection Guide
ENPDF 2.61 MB
Datasheet
ENPDF 17.4 MB
Technical Manual
ENPDF 2.33 MB
Users Manual
ENPDF 12.3 MB
Datasheet
ENPDF 81.2 MB
Instruction Sheet
ENPDF 1.14 MB
Users Manual
ENPDF 1.71 MB
Instruction Sheet
ENPDF 1.19 MB
Operation Manual
ENPDF 1.12 MB
Instruction Sheet
ENPDF 1.15 MB
Users Manual
ENPDF 12.5 MB
Users Manual
ENPDF 2.69 MB
Users Manual
ENPDF 4.11 MB
Users Manual
ENPDF 12.3 MB
Instruction Sheet
ENPDF 546 KB
Datasheet
ENPDF 16.7 MB
Instruction Sheet
ENPDF 568 KB
Instruction Sheet
ENPDF 690 KB
Instruction Sheet
ENPDF 576 KB
Instruction Sheet
ENPDF 1.95 MB
Instruction Sheet
ENPDF 1.35 MB
Instruction Sheet
ENPDF 649 KB
Instruction Sheet
ENPDF 601 KB
Instruction Sheet
ENPDF 490 KB
Instruction Sheet
ENPDF 915 KB
Instruction Sheet
ENPDF 1.2 MB
Users Manual
ENPDF 15.1 MB
Instruction Sheet
ENPDF 605 KB
Datasheet
ENPDF 12.9 MB
Users Manual
ENPDF 18.8 MB
Users Manual
ENPDF 23.3 MB
Users Manual
ENPDF 18.6 MB