Valve function |
5/2, bistable5/2 or 3/2 switchable5/3, pressurized5/3, exhausted5/3, closed |
Actuation type |
Electrical |
Width |
32 mm |
Standard nominal flow rate |
800 l/min … 1350 l/min |
Pneumatic working port |
NAMUR connection diagram |
Operating voltage |
110V AC120V AC12V DC230V AC240V AC24V AC24V DC48V AC48V DCVia solenoid coil, to be ordered separately |
Operating pressure |
1.5 bar … 10 bar |
Structural design |
Piston gate valvePlate seat |
Reset method |
Mechanical spring |
Certification |
c UL us – Recognized (OL) |
CE marking (see declaration of conformity) |
as per EU explosion protection directive (ATEX)As per EU low voltage directive |
Explosion protection certification outside the EU |
Class I, Div. 1 (US)Class I, Div. 2 (US)Class II, Div. 1 (US)Class II, Div. 2 (US)Class III, Div. 1 (US)Class III, Div. 2 (US)EPL Da (IEC-EX)EPL Db (IEC-EX)EPL Db (KR)EPL Dc (KR)EPL Ga (IEC-EX)EPL Ga (KR)EPL Gb (IEC-EX)EPL Gb (KR)EPL Gc (KR) |
Certificate issuing authority |
DNVGL-TAA000011J |
ATEX category gas |
II 2GII 3G |
ATEX category for dust |
II 2DII 3D |
Type of ignition protection for gas |
AEx m II T4Ex db IIC T4 GbEx db IIC T5 GbEx ia IIC T6 GaEx ia IIC T6…T5 GaEx mb IIC T6Ex nA IIC T5 X Gc |
Type of (ignition) protection for dust |
Ex ia IIIB T135°C DaEx mb tb IIIC T80°CEx t IIIC T80°C DbEx tb IIIC T100°C DbEx tb IIIC T135°C DbEx tc IIIC T95°C X Dc |
Explosive ambient temperature |
-20°C <= Ta <= +50°C-20°C <= Ta <= +60°C-40°C <= Ta <= +50°C-40°C <= Ta <= +65°C-65°C <= Ta <= +40°C-65°C <= Ta <= +55°C |
Degree of protection |
IP65IP66IP67With plug socketas per IEC 60529 |
Exhaust air function |
With flow control option |
Sealing principle |
Soft |
Mounting position |
Any |
Conforms to standard |
VDI/VDE 3845 (NAMUR) |
Manual override |
DetentingNoneNon-detentingCovered |
Type of control |
Pilot-controlled |
Pilot air supply port |
Internal |
Flow direction |
Non-reversible |
Symbol |
00991005009910180099102100991080009910820099108300991728009918310099195300995701 |
Lap |
OverlapUnderlap |
Signal status display |
With accessories |
b-value |
0.4 … 0.5 |
C value |
2.1 l/sbar … 5.6 l/sbar |
Standard nominal flow rate, exhaust air return 4->3 |
110 l/min |
Switching time off |
6 ms … 120 ms |
On switching time |
4 ms … 35 ms |
Changeover time |
2 ms … 55 ms |
Duty cycle |
100% |
Coil characteristics |
110/120 V AC: 50/60 Hz, initial power 2.7 VA, holding power 1.9 VA110/120 V AC: 50/60 Hz, initial power 4.4 VA, holding power 3.3 VA110/120 V AC: 50/60 Hz, initial power 5.2 VA, holding power 3.1 VA110/120 V AC: 50/60 Hz, initial power 6.9 VA, holding power 3.1 VA110 V AC: 50/60 Hz, initial power 7.7 VA, holding power 3.8 VA120 V AC: 60 Hz, initial power 10.0 VA, holding power 6.8 VA12 V DC: 2.8 W12 V DC: 3.4 W230/240 V AC: 50/60 Hz, initial power 3.9 VA, holding power 2.8 VA230/240 V AC: 50/60 Hz, initial power 5.8 VA, holding power 4.6 VA230 V AC: 50/60 Hz, initial power 10.0 VA, holding power 6.0 VA230 V AC: 50/60 Hz, initial power 11.5 VA, holding power 8.0 VA230 V AC: 50/60 Hz, initial power 6.2 VA, holding power 3.7 VA230 V AC: 50/60 Hz, initial power 6.9 VA, holding power 4.1 VA24 V DC: 0.8 W24 V DC: 2.1 W24 V DC: 3.3 W24 V DC: 4.6 W24 V AC: 50/60 Hz, initial power 2.5 VA, holding power 1.7 VA24 V AC: 50/60 Hz, initial power 3.9 VA, holding power 2.6 VA24 V DC: 0.7 W24 V DC: 1.2 W24 V DC: 2.6 W48 V AC: 50/60 Hz, initial power 2.5 VA, holding power 1.7 VA48 V AC: 50/60 Hz, initial power 3.9 VA, holding power 2.7 VA48 V DC: 2.8 W48 V DC: 3.4 WSee solenoid coil, to be ordered separately |
Permissible voltage fluctuations |
+/- 10 % |
Explosion prevention and protection |
Zone 0 (KR)Zone 1 (ATEX)Zone 2 (ATEX)Zone 21 (ATEX)Zone 22 (ATEX)Zone 0 (IEC-EX)Zone 1 (IEC-EX)Zone 20 (IEC-EX)Zone 21 (IEC-EX)Zone 1 (KR)Zone 2 (KR)Zone 21 (KR)Zone 22 (KR)Class I, Div. 1 (US)Class I, Div. 2 (US)Class II, Div. 1 (US)Class II, Div. 2 (US)Class III, Div. 1 (US)Class III, Div. 2 (US) |
Operating medium |
Compressed air as per ISO 8573-1:2010 [7:4:4] |
Information on operating and pilot media |
Operation with oil lubrication possible (required for further use) |
Corrosion resistance class (CRC) |
2 – Moderate corrosion stress |
Temperature of medium |
-20 °C … 60 °C |
Ambient temperature |
-20 °C … 60 °C |
Product weight |
335 g … 685 g |
Electrical connection |
3-pinForm AForm BCable connector M20x1.5Plugas per EN 175301-803As per industrial standard (11 mm) |
Type of mounting |
With through-hole |
Venting hole connection |
Not ducted |
Pneumatic connection 1 |
G1/41/4 NPTQS-6QS-8QS-10QS-1/4QS-5/16QS-3/8 |
Pneumatic connection 2 |
NAMUR connection diagram |
Pneumatic connection 3 |
G1/41/4 NPTQS-6QS-8QS-10QS-1/4QS-5/16QS-3/8 |
Pneumatic connection 4 |
NAMUR connection diagram |
Pneumatic connection 5 |
G1/41/4 NPTQS-6QS-8QS-10QS-5/16QS-1/4QS-3/8 |
Note on materials |
RoHS-compliant |
Seals material |
NBR |
Housing material |
Wrought aluminum alloy |
Material of screws |
High-alloy stainless steel |
Reviews