| Dimensions W x L x H | 
(incl. interlinking block and connection system)50 mm x 107 mm x 70 mm | 
| No. of inputs | 
8  | 
| CE marking (see declaration of conformity) | 
as per EU explosion protection directive (ATEX) | 
| Explosion protection certification outside the EU | 
EPL Da (BR)EPL Da (IEC-EX)EPL Ga (BR)EPL Ga (IEC-EX) | 
| Explosion prevention and protection | 
Zone 0 (BR)Zone 20 (BR)Zone 0 (IEC-EX)Zone 20 (IEC-EX) | 
| Certificate issuing authority | 
DNV 15.0192 XIECEx ZLM 12.0007 XZELM 12 ATEX 0500 X | 
| ATEX category gas | 
II (1) G | 
| ATEX category for dust | 
II (1) D | 
| Type of ignition protection for gas | 
[Ex ia Ga] IIC | 
| Type of (ignition) protection for dust | 
[Ex ia Da] IIIC | 
| Explosive ambient temperature | 
-5°C <= Ta <= +50°C | 
| Corrosion resistance class (CRC) | 
2 – Moderate corrosion stress(when installed) | 
| Storage temperature | 
-20 °C … 70 °C | 
| Relative air humidity | 
95 %Non-condensing | 
| Degree of protection | 
IP20 | 
| Ambient temperature | 
-5 °C … 50 °C | 
| Product weight | 
100 g | 
| Electrical connection | 
8-pin/8-pin | 
| Type of mounting | 
On interlinking block CPX-M-GE… | 
| Note on materials | 
RoHS-compliant | 
| Housing material | 
PA-reinforced | 