Dimensions W x L x H |
(incl. interlinking block and connection system)50 mm x 107 mm x 70 mm |
Width dimension |
50 mm |
No. of inputs |
8 |
Diagnostics |
Wire break per channelLimit value violation per channelShort circuit per channelParameterization error |
Parameterization |
Data formatInput debouncing time per channelInput function per channelReplacement value in diagnostic case per channelSignal extension time per channelGate time per channelLimit value monitoring per channelShort circuit monitoring per channelParameter monitoringCounter configuration per channelUpper limit per channelLower limit value per channelWire break monitoring per channel |
Reverse polarity protection |
for operating voltage |
Additional functions |
Frequency measurementCounter function |
Control elements |
DIL switch |
LED indicators |
1 group diagnostics8 channel diagnostics8 channel status |
Input debounce time |
3 ms (0 ms, 10 ms, 20 ms parameterizable) |
Fuse protection (short circuit) |
Per channel |
Intrinsic current consumption at nominal operating voltage |
Typ. 75 mA |
Max. power output Po |
0.042 W |
Max. output voltage Vo |
10 V |
Max. output current Io |
0.017 A |
Max. external inductance Lo |
125 mH |
Max. external capacitance Co |
3000 nF |
Nominal operating voltage DC |
24 V |
Power failure buffering |
20 ms |
Electrical isolation between channel and internal bus |
yes |
Electrical isolation between channels |
no |
Residual ripple |
0.4 Vss |
Switching level |
as per EN 60947-5-6 |
Permissible voltage fluctuations |
+/- 25 % |
CE marking (see declaration of conformity) |
as per EU explosion protection directive (ATEX) |
Explosion protection certification outside the EU |
EPL Da (BR)EPL Da (IEC-EX)EPL Ga (BR)EPL Ga (IEC-EX) |
Explosion prevention and protection |
Zone 0 (BR)Zone 20 (BR)Zone 0 (IEC-EX)Zone 20 (IEC-EX) |
Certificate issuing authority |
DNV 15.0192 XIECEx ZLM 12.0007 XZELM 12 ATEX 0500 X |
ATEX category gas |
II (1) G |
ATEX category for dust |
II (1) D |
Type of ignition protection for gas |
[Ex ia Ga] IIC |
Type of (ignition) protection for dust |
[Ex ia Da] IIIC |
Explosive ambient temperature |
-5°C <= Ta <= +70°C |
Storage temperature |
-20 °C … 70 °C |
Relative air humidity |
95 %Non-condensing |
Degree of protection |
Depends on manifold block |
Ambient temperature |
-5 °C … 50 °C |
Product weight |
100 g |
Input characteristics |
as per EN 60947-5-6 |
Max. cable length |
200 m |
Type of mounting |
On interlinking block CPX-M-GE… |
Note on materials |
RoHS-compliant |
Housing material |
PA-reinforcedPC |
Reviews