Dimensions W x L x H |
30 mm x 170 mm x 35 mm |
Diagnostics via LED |
Diagnostics per channelDiagnostics per moduleLoad power supplyStatus per channelStatus per module |
Diagnose per internal communication |
IO-Link® eventShort circuit/overload in sensor supplyElectronics/sensors overvoltageLoad overvoltageElectronics/sensors undervoltageLoad undervoltage |
Reverse polarity protection |
yes |
Intrinsic current consumption at nominal operating voltage for electronics/sensors |
Typically 55 mA |
Intrinsic current consumption at nominal operating voltage load |
Typically 5 mA |
Note regarding operating voltage |
SELV/PELV fixed power supplies requiredNote voltage drop |
Max. power supply |
2 x 4 A (external fuse required) |
Nominal operating voltage DC for electronics/sensors |
24 V |
Nominal operating voltage DC load |
24 V |
Power failure buffering |
10 ms |
Permissible voltage fluctuations for electronics/sensors |
± 25 % |
Permissible voltage fluctuations load |
± 25 % |
Power supply, function |
Incoming electronics/sensors and load |
Power supply, type of connection |
Plug |
Power supply, connection technology |
M8x1, A-coded as per EN 61076-2-104 |
Power supply, number of pins/wires |
4 |
Voltage forwarding, function |
Outgoing electronics/sensors and load |
Voltage forwarding, connection type |
Socket |
Voltage forwarding, connection technology |
M8x1, A-coded as per EN 61076-2-104 |
Voltage forwarding, number of pins/wires |
4 |
Certification |
RCM compliance mark |
KC characters |
KC EMC |
CE marking (see declaration of conformity) |
As per EU EMC directive |
UKCA marking (see declaration of conformity) |
To UK instructions for EMC |
Corrosion resistance class (CRC) |
1 – Low corrosion stress |
Storage temperature |
-40 °C … 70 °C |
Relative air humidity |
5 – 95 %Non-condensing |
Degree of protection |
IP65IP67 |
Note on degree of protection |
Unused connections sealed |
Ambient temperature |
-20 °C … 50 °C |
Product weight |
126 g |
Protocol |
IO-Link® |
IO-Link®, protocol version |
Master V 1.1 |
IO-Link®, communication mode |
Configurable via softwareSIO, COM1 (4.8 kBd), COM2 (38.4 kBd), COM3 (230.4 kBd) |
IO-Link®, port class |
B |
IO-Link®, number of ports |
4 |
IO-Link®, process data width OUT |
8–128 bytes parameterizable |
IO-Link®, process data width IN |
12–132 bytes parameterizable |
IO-Link®, minimum cycle time |
Depends on minimally supported cycle time of connected IO-Link® device |
Max. cable length |
20 m for IO-Link® operation50 m system communication |
IO-Link®, communication |
C/Q LED green |
Communication interface, function |
System communication XF10 IN / XF20 OUT |
Communication interface, connection type |
2x socket |
Communication interface, connection technology |
M8x1, D-coded as per EN 61076-2-114 |
Communication interface, number of pins/wires |
4 |
Communication interface, protocol |
AP-COM |
Communication interface, shielding |
yes |
Electrical IO-Link® connection, connection type |
4x socket |
Electrical connection, IO-Link®, connection technology |
M12x1, A-coded as per EN 61076-2-101 |
Electrical IO-Link® connection, number of pins/wires |
5 |
Type of mounting |
On H-rail with accessoriesWith through-hole |
Note on materials |
RoHS-compliant |
Housing material |
PAPCDie-cast zinc, nickel-plated |
O-ring material |
FPM |