Description
Product characteristics
| Electrical design | NAMUR |
|---|---|
| Output function | 2 x normally closed |
| Sensing range [mm] | 4 |
| Housing | rectangular |
| Dimensions [mm] | 40 x 26 x 26 |
Electrical data
| Connection to switching amplifiers | yes |
|---|---|
| Switching amplifiers | connection to certified intrinsically safe circuits with the max. values: U = 15 V / I = 50 mA / P = 120 mW |
| Nominal voltage DC [V] | 8.2; (1kΩ) |
| Supply voltage DC [V] | 7.5…15 |
| Current consumption [mA] | < 1; (disabled; conductive: > 2,1) |
| Protection class | III |
Outputs
| Electrical design | NAMUR |
|---|---|
| Output function | 2 x normally closed |
| Switching frequency DC [Hz] | 1800 |
Detection zone
| Sensing range [mm] | 4 |
|---|---|
| Real sensing range Sr [mm] | 4 ± 10 % |
Accuracy / deviations
| Correction factor | steel: 1 / stainless steel: 0.7 / brass: 0.5 / aluminium: 0.4 / copper: 0.3 |
|---|---|
| Hysteresis [% of Sr] | 1…15 |
| Switch point drift [% of Sr] | -10…10 |
Operating conditions
| Ambient temperature [°C] | -20…80 |
|---|---|
| Protection | IP 67 |
Tests / approvals
| Approval | DMT 02 ATEX E028; BVS 04 ATEX E153; TIIS TC17612; IECEx BVS 06.0003 | ||
|---|---|---|---|
| ATEX marking | |||
| EMC |
|
||
| Shock/vibration resistance | 30 g (11 ms) / 10-55 Hz (1 mm) | ||
| MTTF [years] | 1253 |
Safety classification
| Max. internal capacitance [nF] | 140; (per intrinsically safe circuit) |
|---|---|
| Max. internal inductance [µH] | 140; (per intrinsically safe circuit) |
Mechanical data
| Weight [g] | 500.7 |
|---|---|
| Housing | rectangular |
| Mounting | non-flush mountable |
| Dimensions [mm] | 40 x 26 x 26 |
| Materials | housing: PBT; cover: PC |
Displays / operating elements
| Display |
|
|---|
Remarks
| Pack quantity | 1 pcs. |
|---|
Electrical connection
| Connection | Cable: 10 m, silicone; 4 x 0.34 mm² |
|---|