Description
Product characteristics
| Type of light | infrared light |
|---|---|
| Electrical design | PNP |
| Protection | IP 65 |
Application
| Protective function | access prevention body protection |
|---|
Electrical data
| Operating voltage tolerance [%] | 20 |
|---|---|
| Operating voltage [V] | 24 DC |
| Current consumption [mA] | 250 |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time [s] | < 10 |
| Type of light | infrared light |
| Wave length [nm] | 950 |
Outputs
| Electrical design | PNP |
|---|---|
| Number of OSSD outputs | 2 |
| Max. current load per OSSD output [mA] | 500 |
| Short-circuit protection | yes |
Detection zone
| Protected area height [mm] | 910 |
|---|---|
| Number of beams | 4 |
| Protection area width (low light intensity) [m] | 0…6 |
| Protection area width (high light intensity) [m] | 0…6 |
| Active/passive system | yes |
Response times
| Response time [ms] | 10.5 |
|---|
Operating conditions
| Applications | class C to EN 60654-1 weatherproof application |
|---|---|
| Ambient temperature [°C] | -10…55 |
| Max. relative air humidity [%] | 95 |
| Protection | IP 65 |
Tests / approvals
| EMC |
|
||
|---|---|---|---|
| Shock resistance |
|
||
| Vibration resistance |
|
Safety classification
| ESPE type (IEC 61496-1) | 4 | |||
|---|---|---|---|---|
| Complies with the requirements |
|
|||
| Mission time TM [h] | 175200 | |||
| PFH [1/h] | 5,0E-09 |
Mechanical data
| Weight [g] | 9200 |
|---|---|
| Dimensions [mm] | 1136 x 50 x 60 |
| Materials | housing: aluminium; front pane: PC |
| Length L [mm] | 1136 |
Displays / operating elements
| Display |
|
|---|
Accessories
| Items supplied |
|
|---|
Remarks
| Pack quantity | 1 pcs. |
|---|
Electrical connection
| Connection | Connector: 1 x M12; coding: A; Maximum cable length: 100 m; for wire cross-section 1 mm² |
|---|




Reviews