Description
Product characteristics
| Number of inputs and outputs | Number of analogue outputs: 1 | |||
|---|---|---|---|---|
| Measuring range |
|
|||
| Process connection | Clamp DN25…DN40 (1…1,5″) DIN 32676 (ISO 2852) |
Application
| Special feature | Gold-plated contacts | |||
|---|---|---|---|---|
| Measuring element | ceramic-capacitive pressure measuring cell | |||
| Temperature monitoring | no | |||
| Application | flush mountable for the food and beverage industry | |||
| Media | viscous media and liquids with suspended particles; liquids and gases | |||
| Medium temperature [°C] | -25…150 | |||
| Min. bursting pressure |
|
|||
| Pressure rating |
|
|||
| Note on pressure rating |
|
|||
| Vacuum resistance [mbar] | -1000 | |||
| Type of pressure | relative pressure; vacuum | |||
| No dead space | yes | |||
| MAWP (for applications according to CRN) [bar] | 30 |
Electrical data
| Operating voltage [V] | 18…30 DC |
|---|---|
| Min. insulation resistance [MΩ] | 100; (500 V DC) |
| Protection class | III |
| Reverse polarity protection | yes |
| Integrated watchdog | yes |
2-wire
| Current consumption [mA] | 3.5…21.5 |
|---|---|
| Power-on delay time [s] | 1 |
3-wire
| Current consumption [mA] | < 45 |
|---|---|
| Power-on delay time [s] | 0.5 |
Inputs / outputs
| Number of inputs and outputs | Number of analogue outputs: 1 |
|---|
Outputs
| Total number of outputs | 2 |
|---|---|
| Output signal | analogue signal; IO-Link; (configurable) |
| Number of analogue outputs | 1 |
| Analogue current output [mA] | 4…20; (scalable) |
| Max. load [Ω] | 700; (Ub = 24 V; (Ub – 9 V) / 21.5 mA) |
| Short-circuit proof | yes |
| Overload protection | yes |
Measuring/setting range
| Measuring range |
|
||||||
|---|---|---|---|---|---|---|---|
| Analogue start point |
|
||||||
| Analogue end point |
|
||||||
| In steps of |
|
||||||
| Factory setting |
|
Accuracy / deviations
| Repeatability [% of the span] | < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) | ||||||||
|---|---|---|---|---|---|---|---|---|---|
| Characteristics deviation [% of the span] | < ± 0,2; (linearity incl. hysteresis and repeatability, limit value setting to DIN EN IEC 62828-1) | ||||||||
| Linearity deviation [% of the span] | < ± 0,15; (Turn down 1:1) | ||||||||
| Hysteresis deviation [% of the span] | < ± 0,15; (Turn down 1:1) | ||||||||
| Long-term stability [% of the span] | < ± 0,1; (Turn down 1:1; per year) | ||||||||
| Temperature coefficient zero point [% of the span / 10 K] | < ± 0,05 | ||||||||
| Temperature coefficient span [% of the span / 10 K] | < ± 0,15 | ||||||||
| Total deviation over temperature range |
|
||||||||
| Notes on the accuracy / deviation | for further details see section Diagrams and graphs |
Response times
| Damping for the analogue output dAA [s] | 0…4 |
|---|
2-wire
| Step response time analogue output [ms] | 30 |
|---|
3-wire
| Step response time analogue output [ms] | 7 |
|---|
Interfaces
| Communication interface | IO-Link | ||||
|---|---|---|---|---|---|
| Transmission type | COM2 (38,4 kBaud) | ||||
| IO-Link revision | 1.1 | ||||
| Profiles | Digital Measuring Sensor (0x000A), Identification and Diagnosis (0x4000) | ||||
| SIO mode | no | ||||
| Required master port type | A | ||||
| Process data analogue | 3 | ||||
| Min. process cycle time [ms] | 3.2 | ||||
| Supported DeviceIDs |
|
Operating conditions
| Ambient temperature [°C] | -25…80 |
|---|---|
| Storage temperature [°C] | -40…100 |
| Protection | IP 67; IP 68; IP 69K |
Tests / approvals
| EMC |
|
||||
|---|---|---|---|---|---|
| Shock resistance |
|
||||
| Vibration resistance |
|
||||
| MTTF [years] | 323 | ||||
| Note on approval |
|
||||
| UL approval |
|
Mechanical data
| Weight [g] | 392.55 |
|---|---|
| Materials | stainless steel (1.4404 / 316L); PBT |
| Materials (wetted parts) | ceramics (99.9 % Al2O3); stainless steel (1.4435 / 316L); surface characteristics: Ra < 0,4 / Rz 4; PTFE |
| Min. pressure cycles | 100 million |
| Process connection | Clamp DN25…DN40 (1…1,5″) DIN 32676 (ISO 2852) |
Remarks
| Pack quantity | 1 pcs. |
|---|
Electrical connection
| Connection | Connector: 1 x M12; coding: A; Contacts: gold-plated |
|---|
Diagrams and graphs
|
|
|
|---|










Reviews