Structural design |
Mechanical sequence counter with pneumatic actuator |
Reset method |
Manual key or pneumatic signal |
Display |
5-digit |
Actuator drop-off pressure |
0.2 ± 0.1 bar |
Resetting cutout pressure |
0.15 ± 0.1 bar |
Actuator response pressure |
0.6 ± 0.2 bar |
Operating pressure |
2 bar … 8 bar |
Minimum resetting pressure |
2 bar |
Min. pulse length for actuator |
10 ms |
Min. pulse length for reset |
180 ms |
Minimum pause period for actuator |
15 ms |
Minimum pause period for reset |
50 ms |
Explosion prevention and protection |
Zone 1 (ATEX)Zone 2 (ATEX)Zone 21 (ATEX)Zone 22 (ATEX) |
Operating medium |
Compressed air as per ISO 8573-1:2010 [7:4:4] |
Information on operating and pilot media |
Operation with oil lubrication not possible |
Ambient temperature |
0 °C … 60 °C |
Product weight |
150 g |
Type of mounting |
Front panel mounting |
Pneumatic connection |
M5 |