| Symbol | 
00995693 | 
| Degree of protection | 
IP40 | 
| Note on degree of protection | 
IP51 for horizontal installation | 
| Flow rate control range | 
0 l/min … 20 l/min | 
| Note on the flow rate control range | 
The specified flow control range only applies at room temperature. Above room temperature, a reduction of the max. adjustable flow rate may occur. | 
| Flow direction | 
Non-reversible | 
| Operating pressure | 
0 MPa … 0.25 MPa | 
| Operating pressure | 
0 bar … 2.5 bar | 
| Overload pressure | 
0.6 MPa | 
| Overload pressure | 
6 bar | 
| Overload pressure | 
87 psi | 
| Burst pressure | 
1 MPa | 
| Burst pressure | 
10 bar | 
| Burst pressure | 
145 psi | 
| Accuracy of flow rate | 
± (4% o.m.v. + 1.25% FS) | 
| Repetition accuracy in ± %FS | 
1 %FS | 
| Hysteresis in ± %FS | 
2.5 %FS | 
| Linearity error FS | 
2 % | 
| Temperature coefficient | 
0.1 %/K | 
| Valve function | 
2-way proportional flow control valve | 
| Nominal width | 
1.4 mm | 
| Pneumatic connection 1 | 
Internal thread M5 | 
| Pneumatic connection 2 | 
Internal thread M5 | 
| Medium | 
Compressed air to ISO 8573-1:2010 [5:4:1]Inert gasOxygen (oxygen applications according to IEC 60601-1 only on request)Nitrogen | 
| Information on medium | 
Operation with oil lubrication not possible | 
| Special features | 
Oxygen-compatible as per DIN EN 1797 | 
| Ambient conditions | 
Not suitable for use in environments enriched with oxygen according to IEC 60601-1 | 
| Duty cycle | 
100% | 
| Temperature of medium | 
5 °C … 40 °C | 
| Ambient temperature | 
0 °C … 50 °C | 
| Storage temperature | 
-20 °C … 70 °C | 
| Nominal operating voltage DC | 
12 V | 
| DC operating voltage range | 
11.1 V … 13.2 V | 
| Max. current consumption | 
65 mA | 
| Max. electrical power consumption | 
1 W | 
| Electrical connection | 
4-pinM8x1 A-coded as per EN 61076-2-104Plug | 
| Reference value | 
0.2 – 10 V | 
| Analog input signal range | 
0.2 – 10 V | 
| Analog output signal range | 
0.2 – 10 V | 
| Reverse polarity protection | 
for operating voltage connections | 
| Product weight | 
92 g | 
| Seals material | 
EPDMNBR | 
| Cover material | 
PA-reinforced | 
| Note on materials | 
RoHS-compliant | 
| Dimensions W x L x H | 
37 mm x 70 mm x 31 mm | 
| Type of mounting | 
Direct fastening via thread | 
| Mounting position | 
Any | 
| Certification | 
RCM compliance mark | 
| Conforms to standard | 
EN 61000-6-2 (EMC)EN 61000-6-3 (EMC) | 
| KC characters | 
KC EMC | 
| CE marking (see declaration of conformity) | 
As per EU EMC directiveAs per EU RoHS directive | 
| UKCA marking (see declaration of conformity) | 
To UK instructions for EMCTo UK RoHS instructions | 
| LABS (PWIS) conformity | 
VDMA24364 zone III | 
Reviews