Valve function |
3-way proportional pressure control valve |
Type of control |
Direct |
Reset method |
Mechanical spring |
Actuation type |
Electrical |
Mounting position |
Any |
Sealing principle |
Soft |
Symbol |
00995607 |
Ambient temperature |
0 °C … 50 °C |
Temperature of medium |
5 °C … 50 °C |
Storage temperature |
-20 °C … 70 °C |
Dimensions W x L x H |
15 mm x 61 mm x 66 mm |
Pneumatic connection 1 |
Flange |
Pneumatic connection 2 |
Flange |
Pneumatic connection 3 |
Flange |
Seals material |
NBR |
Type of mounting |
With through-holeWith accessoriesOptionally: |
Inlet pressure 1 MPa |
0 MPa … 1.1 MPa |
Inlet pressure 1 |
0 bar … 11 bar |
Inlet pressure 1 psi |
0 psi … 159.5 psi |
Output pressure 2 |
0.001 MPa … 0.2 MPa |
Outlet pressure 2 |
0.01 bar … 2 bar |
Output pressure 2 |
0.145 psi … 29 psi |
Standard nominal flow rate |
7 l/min |
Standard nominal flow rate 2-3 |
3 l/min |
Linearity error FS |
0.5 % |
Repetition accuracy in ± %FS |
0.4 %FS |
Hysteresis in ± %FS |
0.25 %FS |
Temperature coefficient |
0.05 %/K |
Absolute accuracy in ± %FS at room temperature |
0.75 %FS |
Product weight |
55 g |
Operating medium |
Compressed air as per ISO 8573-1:2010 [7:4:4]Inert gas |
Information on operating and pilot media |
Operation with oil lubrication not possible |
Degree of protection |
IP65 |
Certification |
RCM compliance mark |
KC characters |
KC EMC |
CE marking (see declaration of conformity) |
As per EU EMC directiveAs per EU RoHS directive |
UKCA marking (see declaration of conformity) |
To UK instructions for EMCTo UK RoHS instructions |
Note on materials |
RoHS-compliant |
LABS (PWIS) conformity |
VDMA24364 zone III |
Corrosion resistance class (CRC) |
2 – Moderate corrosion stress |
DC operating voltage range |
19 V … 29 V |
Nominal operating voltage DC |
24 V |
Residual ripple |
10 % |
Reference value |
0 – 5 V |
Analog output signal range |
1 – 5 V |
Precision analog output in ± %FS |
2 %FS |
Max. electrical power consumption |
1 W |
Reverse polarity protection |
for all electrical connections |
Short-circuit protection |
For all electrical connections |
Safety instructions |
VEAA/VEAB safety position: if the electrical power supply is lost, the outlet pressure is maintained in uncontrolled form, it may increase or fall – pneumatic valve blocked. |
Display type |
LED |
Electrical connection |
4-pinM8x1Plugas per EN 60947-5-2 |
Housing material |
PA-reinforced |
Reviews