Description
Product characteristics
| Number of inputs and outputs | Number of analogue outputs: 2 | 
|---|---|
| Process connection | threaded connection G 1/2 | 
Application
| Special feature | Gold-plated contacts | ||
|---|---|---|---|
| Media | water; glycol solutions; air; oils | ||
| Note on media | 
  | 
||
| Medium temperature [°C] | -20…90 | ||
| Pressure rating [bar] | 100 | ||
| Pressure rating [Mpa] | 10 | ||
| MAWP (for applications according to CRN) [bar] | 85 | 
Electrical data
| Operating voltage [V] | 18…30 DC | 
|---|---|
| Current consumption [mA] | < 100 | 
| Protection class | III | 
| Reverse polarity protection | yes | 
| Power-on delay time [s] | 10 | 
Inputs / outputs
| Number of inputs and outputs | Number of analogue outputs: 2 | 
|---|
Outputs
| Total number of outputs | 2 | 
|---|---|
| Output signal | analogue signal | 
| Number of analogue outputs | 2 | 
| Analogue current output [mA] | 4…20; (scalable) | 
| Max. load [Ω] | 350 | 
| Short-circuit protection | yes | 
| Type of short-circuit protection | pulsed | 
| Overload protection | yes | 
Measuring/setting range
| Probe length L [mm] | 19.2 | 
|---|---|
| Operating mode | relative; absolutely liquid; absolutely gaseous; (absolute: reference measurement recommended; Factory setting: relative) | 
Temperature monitoring
| Measuring range [°C] | -20…90 | 
|---|---|
| Resolution [°C] | 0.2 | 
| Analogue start point [°C] | -20…76 | 
| Analogue end point [°C] | 4…100 | 
| In steps of [°C] | 0.2 | 
Liquid media – absolute operating mode
| Setting range [m/s] | 0.04…3 | 
|---|---|
| Greatest sensitivity [m/s] | 0.04…3 | 
Liquid media – relative operating mode
| Setting range [m/s] | 0.04…6 | 
|---|---|
| Greatest sensitivity [m/s] | 0.04…3 | 
Gases – operating mode “absolute”
| Setting range [m/s] | 0…100 | 
|---|---|
| Greatest sensitivity [m/s] | 30…100 | 
Gases – operating mode “relative”
| Setting range [m/s] | 0…200 | 
|---|---|
| Greatest sensitivity [m/s] | 30…100 | 
Accuracy / deviations
| Temperature drift [cm/s x 1/K] | 0,003 m/s x 1/K (< 20 °C; > 70 °C) | 
|---|---|
| Temperature gradient [K/min] | 100 | 
Absolute operating mode
| Repeatability | 0,05 m/s; (water; flow velocity: 0,05…3 m/s) | 
|---|
Relative operating mode
| Accuracy | ± (7 % MW + 2 % MEW); (for relative mode in the range of maximum sensitivity under the following conditions:; water: 20…70 °C; inlet length: 1.5 m; DN25 (DIN 2448); mounting position according to instructions; Accuracy can differ for other media and mounting positions.) | 
|---|---|
| Repeatability | 0,05 m/s; (water; flow velocity: 0,05…3 m/s) | 
Temperature monitoring
| Temperature drift | ± 0,005 K/°C | 
|---|---|
| Accuracy [K] | ± 0,3 / ± 1; (water; flow velocity: 0,3…3 m/s / air; flow velocity: > 10 m/s) | 
Response times
| Response time [s] | 0.5; (T09; water; glycol: 0,8 s; air: 7 s; oil: 1,8 s; each T09) | 
|---|
Temperature monitoring
| Dynamic response T05 / T09 [s] | 1,5 (T09); (water; flow velocity: 0,3…3 m/s) | 
|---|
Software / programming
| Parameter setting options | medium selection; Damping; Teach function; display can be rotated and switched off; standard unit of measurement; process value colour | 
|---|
Operating conditions
| Ambient temperature [°C] | -40…80 | 
|---|---|
| Storage temperature [°C] | -40…100 | 
| Protection | IP 65; IP 67 | 
Tests / approvals
| EMC | 
  | 
||||
|---|---|---|---|---|---|
| Shock resistance | 
  | 
||||
| Vibration resistance | 
  | 
||||
| MTTF [years] | 180 | ||||
| UL approval | 
  | 
Mechanical data
| Weight [g] | 296.5 | 
|---|---|
| Materials | stainless steel (1.4404 / 316L); stainless steel (1.4310 / 301); PBT-GF20; PBT-GF30 | 
| Materials (wetted parts) | stainless steel (1.4404 / 316L); Gasket: FKM | 
| Process connection | threaded connection G 1/2 | 
Displays / operating elements
| Display | 
  | 
|---|
Remarks
| Remarks | 
  | 
||
|---|---|---|---|
| Pack quantity | 1 pcs. | 
Electrical connection
| Connection | Connector: 1 x M12; coding: A; Contacts: gold-plated | 
|---|
				
								
								