Valve function |
3-way proportional pressure control valve |
Structural design |
Piston gate valvewith integrated pressure sensors |
Type of control |
Direct |
Actuation type |
Electrical |
Reset method |
Magnetic spring |
Flow direction |
Non-reversible |
Mounting position |
Any |
Sealing principle |
Hard |
Nominal width |
6 mm |
Short-circuit protection |
yes |
Display type |
LED |
Standard nominal flow rate |
725 l/min |
Operating pressure |
0.4 MPa … 0.8 MPa |
Operating pressure |
4 bar … 8 bar |
Typical lowering speed |
15 mm/s |
Note on lowering speed |
When manual exhausting is actuated with cylinder diameter 80 mm, transmission ratio 1:1 and 100 kg load. |
Ambient temperature |
0 °C … 50 °C |
Operating medium |
Compressed air as per ISO 8573-1:2010 [6:4:4] |
Information on operating and pilot media |
Operation with oil lubrication not possibleMaximum particle size 5 µm |
Degree of protection |
IP65 |
Note on degree of protection |
In mounted state |
Certification |
RCM compliance mark |
KC characters |
KC EMC |
CE marking (see declaration of conformity) |
As per EU EMC directiveAs per EU RoHS directive |
UKCA marking (see declaration of conformity) |
To UK instructions for EMCTo UK RoHS instructions |
LABS (PWIS) conformity |
VDMA24364 zone III |
Note on materials |
RoHS-compliant |
Vibration resistance |
Transport application test with severity level 2 as per FN 942017-4 and EN 60068-2-6 |
Shock resistance |
Shock test with severity level 2 as per FN 942017-5 and EN 60068-2-27 |
Corrosion resistance class (CRC) |
1 – Low corrosion stress |
Application note |
The product is suitable for industrial purposes only. Radio interference suppression measures may be required in residential areas. |
Nominal operating voltage DC |
24 V |
DC operating voltage range |
21.6 V … 26.4 V |
Residual ripple |
5 % |
Max. current consumption |
1.2 A |
Current consumption |
120 mA |
Reverse polarity protection |
for operating voltage |
Duty cycle |
100% |
Max. electrical power consumption |
33.5 W |
Diagnostic function |
Indication via LED |
Max. cable length |
30 m |
Fieldbus interface, connection type |
Plug |
Fieldbus interface, connection technology |
M12x1, A-coded as per EN 61076-2-101 |
Fieldbus interface, number of poles/wires |
5 |
Fieldbus interface, protocol |
CAN bus with Festo protocol |
Electrical connection for actuator, connection type |
Socket |
Electrical actuator connection, connection technology |
M12x1 A-coded as per EN 61076-2-101 |
Electrical actuator connection, number of pins/wires |
8 |
Pneumatic valve electrical connection, connection type |
Plug |
Electrical pneumatic valve connection, connection technology |
Connection diagram form C as per industrial standard, 9.4 mm |
Electrical pneumatic valve connection, number of pins/wires |
2 |
Type of mounting |
Direct fastening via M5 thread |
Pneumatic connection 1 |
G3/8 |
Pneumatic connection 2 |
G3/8 |
Pneumatic connection 3 |
G3/8 |
Pneumatic connection for control component |
G1/8 |
Product weight |
1550 g |
Housing material |
Wrought aluminum alloy, anodized |
Seals material |
FPMHNBRNBR |