Description
Product characteristics
| Electrical design | series connection possible | 
|---|---|
| Output function | 2 x normally open | 
| Sensing range [mm] | 4 | 
| Housing | rectangular | 
Electrical data
| Frequency AC [Hz] | 47…63 | 
|---|---|
| Operating voltage [V] | 20…140 AC / 10…140 DC | 
| Protection class | I | 
| Reverse polarity protection | no | 
Outputs
| Electrical design | series connection possible | 
|---|---|
| Output function | 2 x normally open | 
| Max. voltage drop switching output DC [V] | 5 | 
| Max. voltage drop switching output AC [V] | 5 | 
| Minimum load current [mA] | 5 | 
| Max. leakage current [mA] | 1.7 | 
| Permanent current rating of switching output AC [mA] | 200 | 
| Permanent current rating of switching output DC [mA] | 200 | 
| Switching frequency AC [Hz] | 25 | 
| Switching frequency DC [Hz] | 25 | 
| Short-circuit proof | no | 
| Overload protection | no | 
Detection zone
| Sensing range [mm] | 4 | 
|---|---|
| Real sensing range Sr [mm] | 4 ± 10 % | 
| Operating distance [mm] | 0…3.25 | 
Accuracy / deviations
| Correction factor | steel: 1 / stainless steel: 0.7 / brass: 0.5 / aluminium: 0.4 / copper: 0.3 | 
|---|---|
| Hysteresis [% of Sr] | 1…15 | 
| Switch point drift [% of Sr] | -10…10 | 
Operating conditions
| Ambient temperature [°C] | -25…80 | 
|---|---|
| Protection | IP 67 | 
Tests / approvals
| EMC | 
  | 
||||||||
|---|---|---|---|---|---|---|---|---|---|
| MTTF [years] | 514 | ||||||||
| UL approval | 
  | 
Mechanical data
| Weight [g] | 79 | 
|---|---|
| Housing | rectangular | 
| Mounting | non-flush mountable | 
| Materials | PBT | 
Displays / operating elements
| Display | 
  | 
|---|
Electrical connection
| Required protection | miniature fuse to IEC60127-2 sheet 1; ≤ 2 A; fast acting | 
|---|
Remarks
| Remarks | 
  | 
|
|---|---|---|
| Pack quantity | 1 pcs. | 
Electrical connection – plug
| Connector: 1 x 7/8″; coding: A | 
				
								
								






Reviews
There are no reviews yet.