PI2894

  • Robust stainless steel housing for use in the food and beverage industry
  • Hygienic, flush design
  • Resistant to high-pressure cleaning with aggressive cleaning agents
  • High temperature resistance and high protection rating
  • Programmable analogue and switching output

 

SKU: PI2894

$639,40

Description

Product characteristics
Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1
Measuring range
-1…10 bar -14.5…145 psi -0.1…1 MPa
Process connection threaded connection G 1 external thread sealing cone Attention: The unit must only be installed in a process connection for G1 sealing cone.; The G1A sealing cone of the unit is only suited for adapters with metal end stop.
Application
Special feature Gold-plated contacts
Application flush mountable for the food and beverage industry
Media viscous media and liquids with suspended particles; liquids and gases
Medium temperature [°C] -25…125; (145 max. 1h)
Min. bursting pressure
150 bar 2175 psi 15 MPa
Pressure rating
50 bar 725 psi 5 Mpa
Vacuum resistance [mbar] -1000
Type of pressure relative pressure; vacuum
MAWP (for applications according to CRN) [bar] 50
Electrical data
Min. insulation resistance [MΩ] 100; (500 V DC)
Protection class III
Reverse polarity protection yes
Integrated watchdog yes
2-wire
Operating voltage [V] 20…32 DC
Current consumption [mA] 3.6…21
Power-on delay time [s] 1
3-wire
Operating voltage [V] 18…32 DC
Current consumption [mA] < 45
Power-on delay time [s] 0.5
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1
Outputs
Total number of outputs 2
Output signal switching signal; analogue signal; IO-Link; (configurable)
Electrical design PNP/NPN
Number of digital outputs 2
Output function normally open / normally closed; (parameterisable)
Number of analogue outputs 1
Analogue current output [mA] 4…20, invertible; (scalable)
Short-circuit protection yes
Type of short-circuit protection pulsed
Overload protection yes
2-wire
Max. load [Ω] 300
3-wire
Max. voltage drop switching output DC [V] 2
Permanent current rating of switching output DC [mA] 250
Switching frequency DC [Hz] 125
Max. load [Ω] (Ub – 10 V) / 20 mA
Measuring/setting range
Measuring range
-1…10 bar -14.5…145 psi -0.1…1 MPa
Set point SP
-0.98…10 bar -14.2…145 psi -0.098…1 MPa
Reset point rP
-1…9.98 bar -14.5…144.7 psi -0.1…0.998 MPa
Analogue start point
-1…7.5 bar -14.5…108.7 psi -0.1…0.75 MPa
Analogue end point
1.5…10 bar 21.8…145 psi 0.15…1 MPa
In steps of
0.01 bar 0.1 psi 0.001 MPa
Factory setting
SP1 = 2.50 bar rP1 = 2.30 bar
SP2 = 7.50 bar rP2 = 7.30 bar
ASP = 0.00 bar AEP = 10.00 bar
Accuracy / deviations
Switch point accuracy [% of the span] < ± 0,2; (Turn down 1:1)
Repeatability [% of the span] < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1)
Characteristics deviation [% of the span] < ± 0,2; (Turn down 1:1 , linearity, incl. hysteresis and repeatability , limit value setting to DIN EN IEC 62828-1)
Linearity deviation [% of the span] < ± 0,15; (Turn down 1:1)
Hysteresis deviation [% of the span] < ± 0,15; (Turn down 1:1)
Long-term stability [% of the span] < ± 0,1; (Turn down 1:1; per year)
Temperature coefficient zero point [% of the span / 10 K] < ± 0,05; (0…70 °C)
Temperature coefficient span [% of the span / 10 K] < ± 0,15; (0…70 °C)
Response times
Damping process value dAP [s] 0…30
Damping for the analogue output dAA [s] 0.01…99.99
2-wire
Step response time analogue output [ms] 45
3-wire
Min. response time of switching output (dAP) [ms] 3
Step response time analogue output [ms] 7
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.0
Profiles no profile
SIO mode yes
Required master port type A
Process data analogue 1
Process data binary 2
Min. process cycle time [ms] 2.3
Supported DeviceIDs
Type of operation DeviceID
Default 157
Operating conditions
Ambient temperature [°C] -25…80
Storage temperature [°C] -40…100
Protection IP 67; IP 68; IP 69K
Tests / approvals
EMC
EN 61000-4-2 ESD 4 kV CD / 8 kV AD
EN 61000-4-3 HF radiated 10 V/m
EN 61000-4-4 Burst 2 kV
EN 61000-4-5 Surge 0,5/1 kV
EN 61000-4-6 HF conducted 10 V
Shock resistance
DIN IEC 68-2-27 50 g (11 ms)
Vibration resistance
DIN IEC 68-2-6 20 g (10…2000 Hz)
MTTF [years] 148.85
Mechanical data
Weight [g] 378.5
Materials stainless steel (1.4404 / 316L); FKM; PTFE; PBT; PEI; PFA
Materials (wetted parts) ceramics (99.9 % Al2O3); stainless steel (1.4435 / 316L); surface characteristics: Ra < 0,4 / Rz 4; PTFE
Min. pressure cycles 100 million
Process connection threaded connection G 1 external thread sealing cone Attention: The unit must only be installed in a process connection for G1 sealing cone.; The G1A sealing cone of the unit is only suited for adapters with metal end stop.
Displays / operating elements
Display
Display unit LED, green
switching status LED, yellow
function display alphanumeric display, 4-digit
measured values alphanumeric display, 4-digit
Display unit bar; psi; MPa; % of the span
Remarks
Pack quantity 1 pcs.
Electrical connection
Connection Connector: 1 x M12; coding: A; Contacts: gold-plated

 

PI2894

Datasheet
EN PDF

Reviews

There are no reviews yet.

Be the first to review “PI2894”