Description
Product characteristics
| Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 | ||
|---|---|---|---|
| Measuring range |
|
||
| Process connection | threaded connection G 1/2 |
Application
| Special feature | Gold-plated contacts | ||
|---|---|---|---|
| Application | for industrial applications | ||
| Media | Liquids; water; glycol solutions; coolants | ||
| Note on media |
|
||
| Medium temperature [°C] | -10…100 | ||
| Min. bursting pressure [bar] | 160 | ||
| Pressure rating [bar] | 40 | ||
| Pressure rating [Mpa] | 4 | ||
| MAWP (for applications according to CRN) [bar] | 40 |
Electrical data
| Operating voltage [V] | 18…30 DC; (to SELV/PELV) |
|---|---|
| Current consumption [mA] | < 50 |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time [s] | < 3 |
Inputs / outputs
| Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
|---|
Outputs
| Total number of outputs | 2 |
|---|---|
| Output signal | switching signal; analogue signal; frequency signal; IO-Link; (configurable) |
| Number of digital outputs | 2 |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC [V] | 2 |
| Permanent current rating of switching output DC [mA] | 150; (per output 2 x 200 (…60 °C); 2 x 250 (…40 °C)) |
| Switching cycles (mechanical) | 10 million |
| Number of analogue outputs | 1 |
| Analogue current output [mA] | 4…20 |
| Max. load [Ω] | 500 |
| Short-circuit protection | yes |
| Overload protection | yes |
| Frequency of the output [Hz] | 0…10000 |
Measuring/setting range
| Measuring range |
|
||
|---|---|---|---|
| Display range |
|
||
| Resolution |
|
||
| Set point SP |
|
||
| Reset point rP |
|
||
| Frequency end point, FEP |
|
||
| In steps of |
|
||
| Frequency at the end point FRP [Hz] | 10…10000 | ||
| Measuring dynamics | 1:50 |
Temperature monitoring
| Measuring range [°C] | -10…100 |
|---|---|
| Display range [°C] | -32…122 |
| Resolution [°C] | 1 |
| Set point SP [°C] | -9…100 |
| Reset point rP [°C] | -10…99 |
| In steps of [°C] | 1 |
| Frequency start point, FSP [°C] | -10…78 |
| Frequency end point, FEP [°C] | 12…100 |
| Frequency at the end point FRP [Hz] | 10…10000 |
Accuracy / deviations
Flow monitoring
| Accuracy (in the measuring range) | ± (4 % MW + 1 % MEW); (Q > 0,5 l/min; medium and operating temperature: +22 °C ± 4K) |
|---|---|
| Repeatability | ± 1 % MEW |
Temperature monitoring
| Temperature drift | 0,029 °C / K |
|---|---|
| Accuracy [K] | 3 K (25°C; Q > 1 l/min) |
Response times
Flow monitoring
| Response time [s] | 0.01 |
|---|---|
| Damping process value dAP [s] | 0…5 |
| Damping for the analogue output dAA [s] | 0…5 |
Temperature monitoring
| Dynamic response T05 / T09 [s] | T09 = 120 (Q > 1 l/min) |
|---|
Software / programming
| Parameter setting options | hysteresis / window; normally open / normally closed; switching logic; current/frequency output; medium selection; damping for the switching output / analogue output; display can be rotated and switched off; standard unit of measurement; process value colour |
|---|
Interfaces
| Communication interface | IO-Link | ||||
|---|---|---|---|---|---|
| Transmission type | COM2 (38,4 kBaud) | ||||
| IO-Link revision | 1.1 | ||||
| SDCI standard | IEC 61131-9 CDV | ||||
| Profiles | Smart Sensor: Process Data Variable; Device Identification | ||||
| SIO mode | yes | ||||
| Required master port type | A | ||||
| Process data analogue | 2 | ||||
| Process data binary | 2 | ||||
| Min. process cycle time [ms] | 5 | ||||
| Supported DeviceIDs |
|
Operating conditions
| Ambient temperature [°C] | 0…60 | ||
|---|---|---|---|
| Note on ambient temperature |
|
||
| Storage temperature [°C] | -15…80 | ||
| Protection | IP 65; IP 67 |
Tests / approvals
| EMC |
|
||||
|---|---|---|---|---|---|
| Shock resistance |
|
||||
| Vibration resistance |
|
||||
| MTTF [years] | 145 | ||||
| UL approval |
|
||||
| Pressure Equipment Directive | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Mechanical data
| Weight [g] | 750 |
|---|---|
| Materials | stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC; brass chemically nickel-plated |
| Materials (wetted parts) | stainless steel (316 / 1.4401); stainless steel (1.4404 / 316L); brass (2.0371); brass chemically nickel-plated; PPS; O-ring: FKM |
| Process connection | threaded connection G 1/2 |
Displays / operating elements
| Display |
|
|---|
Remarks
| Remarks |
|
||||
|---|---|---|---|---|---|
| Notes | Please note the changed housing design! | ||||
| Pack quantity | 1 pcs. |
Electrical connection
| Connection | Connector: 1 x M12; coding: A; Contacts: gold-plated |
|---|
Diagrams and graphs
|
|
|
|---|








Reviews
There are no reviews yet.