SD2501

  • Precise measurement of flow, consumption, pressure and medium temperature
  • High accuracy, repeatability and measurement dynamics
  • For detecting compressed air in industrial use
  • Red/green display for clear identification of the acceptable range
  • Display can be rotated for optimum alignment

 

SKU: SD2501

$1.026,90

Description

Product characteristics
Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1
Process connection threaded connection 2″ NPT DN50
Pressure monitoring
Measuring range [psi] -15…232
Application
Application for industrial applications
Media compressed air
Medium temperature [°C] -10…60
Min. bursting pressure [psi] 928
Pressure rating [psi] 232
MAWP (for applications according to CRN) [bar] 9.5
Electrical data
Operating voltage [V] 18…30 DC; (to SELV/PELV)
Current consumption [mA] < 80
Protection class III
Reverse polarity protection yes
Power-on delay time [s] 1
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1
Inputs
Inputs counter reset
Outputs
Output signal switching signal; analogue signal; pulse signal; IO-Link; (configurable)
Electrical design PNP/NPN
Number of digital outputs 2
Output function normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V] 2.5
Permanent current rating of switching output DC [mA] 150; (per output)
Number of analogue outputs 1
Analogue current output [mA] 4…20; (scalable)
Max. load [Ω] 500
Pulse output consumed quantity meter
Short-circuit protection yes
Type of short-circuit protection pulsed
Overload protection yes
Measuring/setting range
Measuring range
80…24720 scfh 1.5…412 scfm 1…275.6 ft/s
Display range
0…29660 scfh 0…494.5 scfm 0…330.8 ft/s
Resolution
20 scfh 0.5 scfm 0.2 ft/s
Set point SP
210…24710 scfh 3.5…411.8 scfm 2.4…275.5 ft/s
Reset point rP
90…24590 scfh 1.5…409.8 scfm 1…274.1 ft/s
Analogue start point ASP
0…19780 scfh 0…329.6 scfm 0…220.5 ft/s
Analogue end point AEP
4940…24720 scfh 82.4…412 scfm 55.1…275.6 ft/s
Low flow cut-off LFC
70…250 scfh 1.2…4.1 scfm 0.8…2.8 ft/s
In steps of
1 scfh 0.1 scfm 0.1 ft/s
Pressure monitoring
Measuring range [psi] -15…232
Display range [psi] -15…290
Resolution [psi] 1
Set point SP [psi] -13…232
Reset point rP [psi] -15…231
Analogue start point [psi] -15…186
Analogue end point [psi] 32…232
In steps of [psi] 1
Volumetric flow quantity monitoring
Measuring range
0…100000000 m³ 0…353146667.2 scf
Display range
0…100000000 m³ 0…353146667.2 scf
Set point SP
0.001…10000000 m³ 0.05…353146667.2 scf
Pulse value
0.001…10000000 m³ 0.05…353146667.2 scf
In steps of
0.0001 m³ 0.005 scf
Pulse length [s] 0.002…2
Temperature monitoring
Measuring range
-10…60 °C 14…140 °F
Display range
-24…74 °C -11.2…165.2 °F
Resolution
0.2 °C 0.5 °F
Set point SP
-9.7…60 °C 14.6…140 °F
Reset point rP
-10…59.7 °C 14…139.4 °F
Analogue start point
-10…46 °C 14…114.8 °F
Analogue end point
4…60 °C 39.2…140 °F
In steps of
0.1 °C 0.1 °F
Accuracy / deviations
Temperature coefficient [1/K] ± 0,07 % MW
Accuracy (in the measuring range) class 141: ± (2 % MW + 0,5 % MEW); class 344: ± (6 % MW + 0,6 % MEW) ; air quality to ISO 8573-1:2010; at medium temperature 73 °F
Repeatability ± (0,4 % MW + 0,1 % MEW)
Pressure monitoring
Repeatability [% of the final value] ± 0,2
Characteristics deviation [% of the final value] < ± 0,5; (BFSL = Best Fit Straight Line)
Greatest TEMPCO of the span [% MEW / 10 K] ± 0,3
Greatest TEMPCO of the zero point [% MEW / 10 K] ± 0,1
Temperature monitoring
Accuracy [K] ± 0,5; (medium flow in the limit area of the flow measurement range)
Response times
Response time [s] 0.1; (dAP = 0)
Damping process value dAP [s] 0…5
Pressure monitoring
Response time [s] 0.05
Temperature monitoring
Dynamic response T05 / T09 [s] T09 = 0,5
Software / programming
Parameter setting options hysteresis / window; normally open / normally closed; current/pulse output; display can be rotated and switched off; Display unit; totaliser
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9 CDV
Profiles Digital Measuring Sensor (0x800A), Identification and Diagnosis (0x4000)
SIO mode yes
Required master port type A
Process data analogue 8
Process data binary 2
Min. process cycle time [ms] 7.2
Supported DeviceIDs
Type of operation DeviceID
Default 871
Operating conditions
Ambient temperature [°F] 32…140
Storage temperature [°F] -4…185
Max. relative air humidity [%] 90
Protection IP 65; IP 67
Tests / approvals
EMC
DIN EN 60947-5-9
Vibration resistance
DIN EN 68000-2-6 5 g (10…2000 Hz)
MTTF [years] 183
UL approval
UL Approval no. I012
File number UL E174189
Pressure Equipment Directive Sound engineering practice; can be used for stable gases fluid group 2
Mechanical data
Weight [g] 2681.5
Materials PBT+PC-GF30; PPS GF40; stainless steel (1.4301 / 304); stainless steel (1.4305 / 303); steel (1.5523) galvanised; 2.0401 (brass / CW614N); FKM
Materials (wetted parts) stainless steel (1.4301 / 304); stainless steel (1.4305 / 303); FKM; ceramics glass passivated; PPS GF40; Al2O3 (ceramics); acrylate
Process connection threaded connection 2″ NPT DN50
Displays / operating elements
Display
colour display 1,44″, 128 x 128 pixels
2 x LED, yellow
Remarks
Remarks
SD2501-00_EN-US

Datasheet
EN PDF

Reviews

There are no reviews yet.

Be the first to review “SD2501”

Your email address will not be published. Required fields are marked *