Description
Product characteristics
| Number of inputs and outputs | Number of digital outputs: 1; Number of analogue outputs: 1 | ||
|---|---|---|---|
| Measuring range |
|
||
| Process connection | diameter Ø 6 mm | ||
| Installation length EL [mm] | 100 |
Application
| Special feature | Gold-plated contacts |
|---|---|
| Measuring element | 1 x Pt 1000 |
| Reference element | 1 x NTC |
| Media | liquids and gases |
| Pressure rating [bar] | 160 |
Electrical data
| Operating voltage [V] | 18…32 DC; (“supply class 2” to cULus) |
|---|---|
| Current consumption [mA] | 10; (24 V) |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time [s] | 6 |
| Integrated watchdog | yes |
Inputs / outputs
| Number of inputs and outputs | Number of digital outputs: 1; Number of analogue outputs: 1 |
|---|
Outputs
| Total number of outputs | 2 |
|---|---|
| Output signal | analogue signal; IO-Link; calibration check status |
| Electrical design | PNP/NPN |
| Number of digital outputs | 1 |
| Output function | normally closed; (diagnostic signal) |
| Max. voltage drop switching output DC [V] | 2 |
| Permanent current rating of switching output DC [mA] | 100 |
| Diagnostic output | calibration check status and error diagnostics |
| Number of analogue outputs | 1 |
| Analogue current output [mA] | 4…20 |
| Max. load [Ω] | (Ub – 15 V) x 50 |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Overload protection | yes |
Measuring/setting range
| Measuring range |
|
||
|---|---|---|---|
| Note on measuring range |
|
||
| Factory setting | -10…150 °C / 14…302 °F | ||
| Calibration check limit [K] | 0.5…3 | ||
| In steps of [K] | 0.05 |
Resolution
| Resolution of analogue output [K] | 0.05 |
|---|
Accuracy / deviations
| Precision analogue output [K] | ± 0,2 |
|---|---|
| Precision IO-Link [K] | ± 0,2 |
| Temperature coefficient analogue output [% of the span / 10 K] | < ± 0,02; (in case of deviation from the reference condition 25 ± 5 °C) |
| Temperature coefficient IO-Link [% of the span / 10 K] | < ± 0,01; (in case of deviation from the reference condition 25 ± 5 °C) |
Response times
| Dynamic response T05 / T09 [s] | 1,5 / 4 |
|---|
Software / programming
| Parameter setting options | Display unit; scaling of the analogue output; calibration check limit; switching logic diagnostic output; simulation mode |
|---|
Interfaces
| Communication interface | IO-Link | ||||
|---|---|---|---|---|---|
| Transmission type | COM2 (38,4 kBaud) | ||||
| IO-Link revision | 1.1 | ||||
| SDCI standard | IEC 61131-9 CDV | ||||
| Profiles | Digital Measuring Sensor, Common Profile, Blob Transfer | ||||
| SIO mode | yes | ||||
| Required master port type | A | ||||
| Process data analogue | 1 | ||||
| Process data binary | 1 | ||||
| Min. process cycle time [ms] | 4.4 | ||||
| IO-Link resolution temperature [K] | 0.01 | ||||
| Supported DeviceIDs |
|
Operating conditions
| Ambient temperature [°C] | -25…70 | |
|---|---|---|
| Note on ambient temperature |
|
|
| Storage temperature [°C] | -40…100 | |
| Protection | IP 68; IP 69K |
Tests / approvals
| EMC |
|
||||
|---|---|---|---|---|---|
| Shock resistance |
|
||||
| Vibration resistance |
|
||||
| MTTF [years] | 329 | ||||
| Note on approval |
|
||||
| UL approval |
|
Mechanical data
| Weight [g] | 275.6 |
|---|---|
| Dimensions [mm] | Ø 50 / L = 143.5 |
| Materials | stainless steel (1.4404 / 316L); PEI; FKM; PFA |
| Materials (wetted parts) | stainless steel (1.4404 / 316L); PEEK |
| Process connection | diameter Ø 6 mm |
| Surface characteristics Ra/Rz of the wetted parts | Ra: < 0.8 |
| Probe diameter [mm] | 6 |
| Installation length EL [mm] | 100 |
Remarks
| Remarks |
|
||
|---|---|---|---|
| Pack quantity | 1 pcs. |
Electrical connection
| Connection | Connector: 1 x M12; coding: A; Contacts: gold-plated |
|---|









Reviews
There are no reviews yet.